Spectroscopy and Spectral Analysis, Volume. 35, Issue 2, 309(2015)

The Research on Separating and Extracting Overlapping Spectral Feature Lines in LIBS Using Damped Least Squares Method

WANG Yin*, ZHAO Nan-jing, LIU Wen-qing, YU Yang, FANG Li, MENG De-shuo, HU Li, ZHANG Da-hai, MA Ming-jun, XIAO Xue, WANG Yu, and LIU Jian-guo
Author Affiliations
  • [in Chinese]
  • show less

    In recent years, the technology of laser induced breakdown spectroscopy has been developed rapidly. As one kind of new material composition detection technology, laser induced breakdown spectroscopy can simultaneously detect multi elements fast and simply without any complex sample preparation and realize field, in-situ material composition detection of the sample to be tested. This kind of technology is very promising in many fields. It is very important to separate, fit and extract spectral feature lines in laser induced breakdown spectroscopy, which is the cornerstone of spectral feature recognition and subsequent elements concentrations inversion research. In order to realize effective separation, fitting and extraction of spectral feature lines in laser induced breakdown spectroscopy, the original parameters for spectral lines fitting before iteration were analyzed and determined. The spectral feature line of chromium (CrⅠ: 427.480 nm) in fly ash gathered from a coal-fired power station, which was overlapped with another line(FeⅠ: 427.176 nm), was separated from the other one and extracted by using damped least squares method. Based on Gauss-Newton iteration, damped least squares method adds damping factor to step and adjust step length dynamically according to the feedback information after each iteration, in order to prevent the iteration from diverging and make sure that the iteration could converge fast. Damped least squares method helps to obtain better results of separating, fitting and extracting spectral feature lines and give more accurate intensity values of these spectral feature lines. The spectral feature lines of chromium in samples which contain different concentrations of chromium were separated and extracted. And then, the intensity values of corresponding spectral lines were given by using damped least squares method and least squares method separately. The calibration curves were plotted, which showed the relationship between spectral line intensity values and chromium concentrations in different samples. And then their respective linear correlations were compared. The experimental results showed that the linear correlation of the intensity values of spectral feature lines and the concentrations of chromium in different samples, which was obtained by damped least squares method, was better than that one obtained by least squares method. And therefore, damped least squares method was stable, reliable and suitable for separating, fitting and extracting spectral feature lines in laser induced breakdown spectroscopy.

    Tools

    Get Citation

    Copy Citation Text

    WANG Yin, ZHAO Nan-jing, LIU Wen-qing, YU Yang, FANG Li, MENG De-shuo, HU Li, ZHANG Da-hai, MA Ming-jun, XIAO Xue, WANG Yu, LIU Jian-guo. The Research on Separating and Extracting Overlapping Spectral Feature Lines in LIBS Using Damped Least Squares Method[J]. Spectroscopy and Spectral Analysis, 2015, 35(2): 309

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 6, 2013

    Accepted: --

    Published Online: Feb. 15, 2015

    The Author Email: Yin WANG (yinwang@aiofm.ac.cn)

    DOI:10.3964/j.issn.1000-0593(2015)02-0309-06

    Topics