Infrared and Laser Engineering, Volume. 45, Issue 11, 1117008(2016)

Calibration of retardance deviation for DOLP measurement based spatial modulating spectropolarimeter

Zhang Qiao1, Li Shuang2,3, Liu Qiang2,3, and Gong Ping2,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less

    In order to insure the accuracy in linear polarimetry, a four-beam method was presented to calibrate the retardance of quarter wave plate. The method was based on spatial modulating optical structure, which was composed of quarter wave plate, combo birefringent wedge and polarizer. Variety of polarization measurement and polarization measuring accuracy was researched by simulation approach, when degree of circular polarization of target was changed. It was indicated that the measuring accuracy of Qi, Ui and degree of linear polarization were better than 10-3 with retardance calibration, when degree of linear and circular polarization is randomize between 0.1 to 0.2 and 0 to 0.2 respectively. Accuracy of polarization parameter measuring, except Qi, is about 14 times higher than those without retardance calibrating process.

    Tools

    Get Citation

    Copy Citation Text

    Zhang Qiao, Li Shuang, Liu Qiang, Gong Ping. Calibration of retardance deviation for DOLP measurement based spatial modulating spectropolarimeter[J]. Infrared and Laser Engineering, 2016, 45(11): 1117008

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 光电测量

    Received: Mar. 5, 2016

    Accepted: Apr. 15, 2016

    Published Online: Jan. 20, 2017

    The Author Email:

    DOI:10.3788/irla201645.1117008