Opto-Electronic Engineering, Volume. 37, Issue 5, 133(2010)
Accuracy Analysis and Optimization Design of Constant-diameter Conjugate Focusing Cam
In order to ensure the imaging quality and modulate the focusing plane, a focusing mechanism based on a constant-diameter conjugate cam is designed. To improve focusing accuracy, factors affecting the accuracy of cam are studied. The influences of the roller radial runout, cam machining error and the base circle radius on focusing accuracy are analyzed. Then, a method to guarantee the cam diameter constant and remove return stroke error is studied by using least-squares method. The analysis results indicate that the focusing accuracy can reach ± 4.7 μm, and the return stroke error can reach 4.8 μm. The functioning of institutions is stable and reliable.
Get Citation
Copy Citation Text
HUI Shou-wen, YUAN Guo-qin, DING Ya-lin, LI Yan-wei, LIU Zhe-hua, CHEN Wei. Accuracy Analysis and Optimization Design of Constant-diameter Conjugate Focusing Cam[J]. Opto-Electronic Engineering, 2010, 37(5): 133
Category:
Received: Nov. 10, 2009
Accepted: --
Published Online: Sep. 7, 2010
The Author Email: Shou-wen HUI (hsw_1@sohu.com)
CSTR:32186.14.