Infrared and Laser Engineering, Volume. 32, Issue 2, 123(2003)

Measurement on time-interval in pulsed laser ranging and error analysis

[in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    The traditional digital counting method for time-interval measurement in pulsed laser ranging can't achieve high precision, for it's restricted by the frequency of counting clock. Analog interpolation time-interval measurement has advantages of long measurement range, good linearity and high precision, so it is widely applied for time-interval measurement in pulsed laser ranging. The principle of time-interval measurement by analog interpolation in pulsed laser ranging is introduced. The corresponding time-interval measurement system is designed and studied in experiments. The precision of time-interval measurement reaches up to 100 ps, which corresponds to distance measurement precision at 1.5 cm. In the end, the error of analog interpolation time-interval measurement is analyzed theoretically.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Measurement on time-interval in pulsed laser ranging and error analysis[J]. Infrared and Laser Engineering, 2003, 32(2): 123

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 25, 2002

    Accepted: Oct. 15, 2002

    Published Online: Apr. 28, 2006

    The Author Email:

    DOI:

    Topics