Photonic Sensors, Volume. 4, Issue 2, 102(2014)

Fiber Optic 3-Component Seismometer

Jing HAN, Wentao ZHANG**, Dongshan JIANG, Zhaogang WANG, and and Fang LI
Author Affiliations
  • Optoelectronic System Laboratory, Institute of Semiconductors, Chinese Academy of Sciences, No. 35, Qinghua East Road, Hai dian District Beijing, 100083, China
  • show less

    An all-metal 3-component optical fiber seismometer was proposed and experimentally demonstrated. The theoretical analysis was given based on the electro-mechanical theory. Calibration results showed that the axis sensitivity was about 41 dB (re: 0 dB=1 rad/g) with a fluctuation ±2 dB in the frequency bandwidth of 5 Hz - 400 Hz. A transverse sensitivity of about -40 dB was achieved. The fluctuation of the acceleration sensitivity for the three accelerometers in the seismometer was within ±2.5 dB. The minimum phase demodulation detection accuracy of the phase-generated carrier (PGC) was 10-5 rad/√Hz, and the minimum detectable acceleration was calculated to be 90 ng/√Hz.

    Tools

    Get Citation

    Copy Citation Text

    Jing HAN, Wentao ZHANG*, Dongshan JIANG, Zhaogang WANG, and Fang LI. Fiber Optic 3-Component Seismometer[J]. Photonic Sensors, 2014, 4(2): 102

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Dec. 18, 2013

    Accepted: Jan. 5, 2014

    Published Online: Apr. 9, 2014

    The Author Email: ZHANG* Wentao (zhangwt@semi.ac.cn)

    DOI:10.1007/s13320-014-0173-4