Photonic Sensors, Volume. 4, Issue 1, 28(2014)

Study on Sensitivity Improving of Fiber Bragg Grating Based pH Sensor

Xiongchang LIANG1,2, Shun’er CHEN1,2, Hongbin HUANG1,2, and and Weiping LIU1,3、*
Author Affiliations
  • 1Department of Electronic Engineering, Jinan University, Guangzhou, 510632, China
  • 2Key Laboratory of Optoelectronic Information and Sensing Technologies of Guangdong Higher Educational Institutes, Jinan University, 510632, China
  • 3Optoelectronic and Fiber Sensing Institute of Beijing Pioptics, Beijing,100176, China
  • show less

    The key factor of the sensitivity in the FBG-based pH sensor is analyzed in detail. A multi-thin-layer structure of the gel coated cover was proposed and implemented with a special process. The sensors with the coated thickness of 420 μm, 500 μm, and 580 μm were built up, respectively. The corresponding spectral shifts of 0.08 nm, 0.13 nm, and 0.22 nm were detected when the pH sensors were soaked in the pH value of 3-9. Meanwhile, the sensor with the gel layer thickness of 580 μm was measured in the optimum measurement time period with the pH value changing from 3-12, in which the detected sensitivity of 52 pm/pH was achieved in the pH range of 6-12.

    Tools

    Get Citation

    Copy Citation Text

    Xiongchang LIANG, Shun’er CHEN, Hongbin HUANG, and Weiping LIU. Study on Sensitivity Improving of Fiber Bragg Grating Based pH Sensor[J]. Photonic Sensors, 2014, 4(1): 28

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jul. 1, 2013

    Accepted: Sep. 21, 2013

    Published Online: Jan. 2, 2014

    The Author Email: LIU and Weiping (wpl@jnu.edu.cn)

    DOI:10.1007/s13320-013-0124-5

    Topics