Acta Optica Sinica, Volume. 40, Issue 17, 1712002(2020)

Weight Determination Method for Multi-Site Ground Comprehensive Validation of Optical Sensors

Jingru Liu1,2, Caixia Gao1、*, Yaokai Liu1, Yongguang Zhao1, Lingling Ma1, Shi Qiu1, Chuanrong Li1, Lingli Tang1, Yonggang Qian1, and Ning Wang1
Author Affiliations
  • 1Key Laboratory of Quantitative Remote Sensing Information Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
  • 2School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
  • show less

    The ground validation of radiometric calibration results of optical sensors is comprehensive affected by many uncertainty factors in earth-atmosphere system, which leads to the difference of single verification results in single site, and unable to effectively compare and comprehensively analyze the results. In this study, in consideration of the influence of target characteristics, atmospheric environment, and other factors on the single verification results of single site, a comprehensive weighting method based on weighted average value with the uncertainty of verification results as the weight is proposed to obtain the key comparative reference value (KCRV) closer to the real value, so as to realize the comparison and comprehensive analysis of single site verification results. Meanwhile, the radiometric calibration results of ZY-3/MUX made in China are comprehensively verified based on the ground targets with different reflection characteristics in the national high resolution remote sensing integrated calibration field. The results show that the KCRVs of 12 validation samples in blue, green, red and near-infrared bands are 3.88%、5.42%、6.14%、9.81% respectively, the corresponding uncertainty is 1.79%, 1.87%, 1.96%, and 2.02%, respectively. Among them, the equivalence degrees of 9 validation samples are less than 0.1, prove that the validation results of these samples are closer to KCRV.

    Tools

    Get Citation

    Copy Citation Text

    Jingru Liu, Caixia Gao, Yaokai Liu, Yongguang Zhao, Lingling Ma, Shi Qiu, Chuanrong Li, Lingli Tang, Yonggang Qian, Ning Wang. Weight Determination Method for Multi-Site Ground Comprehensive Validation of Optical Sensors[J]. Acta Optica Sinica, 2020, 40(17): 1712002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Apr. 14, 2020

    Accepted: May. 29, 2020

    Published Online: Aug. 26, 2020

    The Author Email: Gao Caixia (gaocaixia@aoe.ac.cn)

    DOI:10.3788/AOS202040.1712002

    Topics