Spectroscopy and Spectral Analysis, Volume. 33, Issue 6, 1719(2013)
Development of Multi-Spectral Thermometer for Explosion Flame True Temperature Measurement——Field Experiments and Measurement Accuracy Analysis
In the present article, the measurement principle of a multi-target multi-spectral thermometer developed previously is improved in that the brightness temperature approximation method is adopted to overcome the second measurement method initial value selection difficulty. The thermometer is used to measure the explosion true temperature of 3KG TNT explosive in open fields. The experimental results show that this pyrometer can measure changes in the explosion flame true temperature in the whole process, and functions well in the wavefront instantaneous temperature measurement and burning fireball temperature measurement. Finally, through the analysis of the factors which affect the thermometer measurement accuracy, it was concluded that the main error sources restricting the measurement accuracy improvement are still the true temperature algorithm error and the calibration method error. The analysis result has provided the direction for the high-precision thermometer development.
Get Citation
Copy Citation Text
SUN Kun, SUN Xiao-gang, YU Xiao-yang, SUN Xiao-ming. Development of Multi-Spectral Thermometer for Explosion Flame True Temperature Measurement——Field Experiments and Measurement Accuracy Analysis[J]. Spectroscopy and Spectral Analysis, 2013, 33(6): 1719
Received: Jan. 29, 2013
Accepted: --
Published Online: Jun. 7, 2013
The Author Email: Kun SUN (sunkun1982@126.com)