Chinese Journal of Lasers, Volume. 44, Issue 9, 910002(2017)
Harmonic Measurement Error Mechanism and Performance Improvement of Direct-Current Fiber-Optic Current Transformer
The harmonic measurement error mechanism and performance improvement method of the direct-current fiber-optic current transformer (DC FOCT) are investigated. The mathematical models in the discrete domain of the closed-loop signal-detecting system and the moving average output filter are established. The simulation analysis is carried out on the frequency response characteristic of the transformer. The study results show that the forward gain of the closed-loop detection system and the order of the output filter are both crucial factors affecting the harmonic current measurement accuracy. The harmonic current measurement error can be effectively decreased by increasing the forward gain under the condition of the stabilization of the closed-loop system and simultaneously by reducing the order of the output filter. The test platform for the harmonic current measurement error of the DC FOCT is built. The experimental results show that, in the range of 50-1200 Hz, the measurement error of the model machine is less than 0.5% and the bandwidth is more than 10 kHz.
Get Citation
Copy Citation Text
Li Chuansheng, Zhao Wei, Wang Jiafu, Shao Haiming. Harmonic Measurement Error Mechanism and Performance Improvement of Direct-Current Fiber-Optic Current Transformer[J]. Chinese Journal of Lasers, 2017, 44(9): 910002
Category: Remote Sensing and Sensors
Received: Feb. 20, 2017
Accepted: --
Published Online: Sep. 7, 2017
The Author Email: Chuansheng Li (lichsh@nim.ac.cn)