Journal of Applied Optics, Volume. 45, Issue 1, 142(2024)

Detection method for calibration of gas concentrations based on absorption peaks in frequency domain

Jinguo CHAI1... Shancheng YU2, Dandan ZHU1, Lixin KANG1, Zhengtai WANG1, Lulu XU1, Yuxuan REN1 and Kai TONG1,* |Show fewer author(s)
Author Affiliations
  • 1College of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
  • 2Ningbo Institute of Metrology and Testing, Ningbo 310018, China
  • show less

    The traditional optical gas detection method needs to convert the time domain signal to frequency domain signal to obtain the concentration of gas, which will introduce errors in the conversion process and cannot accurately reflect the change of frequency with time, resulting in the gas concentration cannot be accurately calibrated. A detection method based on frequency domain absorption peaks to calibrate gas concentration was proposed. Taking CO2 as an example for detection, the concentration of CO2 in the mixed gas of CO2 and N2 was determined by using the direct absorption method based on the Beer-Lambert law. This method obtained the peak intensity of the absorption spectrum by collecting the light intensity and frequency information of the laser beam and performing the Lorentz fitting by the adjacent averaging method and Levenberg-Marquardt (LM) optimization algorithm. The experimental results show that the linear relationship between laser peak intensity and gas concentration is satisfied, and the Pearson correlation coefficient can reach 0.999. Therefore, the detection method based on the frequency domain absorption peak calibration of gas concentration can effectively simplify the system structure, avoid the effect of frequency drift in the time domain to frequency domain conversion, and make the linearity between laser peak intensity and gas concentration good.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Jinguo CHAI, Shancheng YU, Dandan ZHU, Lixin KANG, Zhengtai WANG, Lulu XU, Yuxuan REN, Kai TONG. Detection method for calibration of gas concentrations based on absorption peaks in frequency domain[J]. Journal of Applied Optics, 2024, 45(1): 142

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Apr. 18, 2023

    Accepted: --

    Published Online: May. 28, 2024

    The Author Email: TONG Kai (童凯(1973—))