Journal of Terahertz Science and Electronic Information Technology , Volume. 21, Issue 1, 77(2023)
Simulation analysis of over-voltage of broken contact line falling on CFRP body of driver's cab
Complexity of the railway operation environment makes it possible to break the contact line, and the broken contact wire falling on the surface of the motor train unit will lead to the overvoltage of the cab body. In order to evaluate the over-voltage damage of Carbon Fiber Reinforced Polymer/Plastic (CFRP) cab body due to its poorer conductivity than that of traditional aluminum alloy cab body, the circuit model of CFRP train body is established based on the semi-CFRP semi-aluminum alloy structure design. The transmission characteristics of surge overvoltage in different positions of the cab body are solved by simulation. The maximum voltage reaches 26 kV, and attenuates rapidly in 60 μs, which is a potential safety hazard for on-board equipment. It is proposed that the grounding wires of on-board equipment should be connected directly near the grounding brush of cab body, which provides a theoretical basis for the design of overvoltage protection of CFRP cab body.
Get Citation
Copy Citation Text
XU Yue, FENG Yuming, BAI Gang, WANG Fuqiang, GUO Wenqing. Simulation analysis of over-voltage of broken contact line falling on CFRP body of driver's cab[J]. Journal of Terahertz Science and Electronic Information Technology , 2023, 21(1): 77
Category:
Received: Oct. 19, 2020
Accepted: --
Published Online: Mar. 14, 2023
The Author Email: Yue XU (xuyue@cqsf.com)