Spectroscopy and Spectral Analysis, Volume. 32, Issue 9, 2327(2012)

Calculation and Analysis of Arc Temperature Field of Pulsed TIG Welding Based on Fowler-Milne Method

XIAO Xiao1,2、*, HUA Xue-ming1,2, WU Yi-xiong1,2, and LI Fang1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Pulsed TIG welding is widely used in industry due to its superior properties, and the measurement of arc temperature is important to analysis of welding process. The relationship between particle densities of Ar and temperature was calculated based on the theory of spectrum, the relationship between emission coefficient of spectra line at 794.8 nm and temperature was calculated, arc image of spectra line at 794.8 nm was captured by high speed camera, and both the Abel inversion and Fowler-Milne method were used to calculate the temperature distribution of pulsed TIG welding.

    Tools

    Get Citation

    Copy Citation Text

    XIAO Xiao, HUA Xue-ming, WU Yi-xiong, LI Fang. Calculation and Analysis of Arc Temperature Field of Pulsed TIG Welding Based on Fowler-Milne Method[J]. Spectroscopy and Spectral Analysis, 2012, 32(9): 2327

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 1, 2012

    Accepted: --

    Published Online: Sep. 26, 2012

    The Author Email: Xiao XIAO (xiaoxiao2788@gmail.com)

    DOI:10.3964/j.issn.1000-0593(2012)09-2327-04

    Topics