Optics and Precision Engineering, Volume. 17, Issue 10, 2425(2009)
Accuracy calibration of alignment system of chip mounter based on grating
Accuracy calibration is a key of the vision alignment system of a high-precision chip mounter,which affects the precision and quality of the chip mounting greatly. For improving the calibration accuracy of the alignment system, this paper presents a new calibration method based on a grating.With proposed method, a group of data similar to quasi-sinusoid signals is abtained by calculating the sum of gray-value of pixels in each column.Then, these calculated data are elaborately converted into a Lissajous figure by pixel translation. The size mapping coefficient between the grating groove and their image pixels of the optical alignment system is calculated to realize the accurate calibration, obtained calibration results indicate that it is coincident with the theoretical calculation results well. A big standard ruler is used to verify the calibration experiment,the error analysis on the experimental data shows that the accuracy error by proposed method is less than 0.2 μm,which can meet the precision needs of vision alignment systems of automatic chip mounters.
Get Citation
Copy Citation Text
LIU Wen-chao, ZHONG Yu-ning, WANG Xuan-ze, XIE Tie-bang. Accuracy calibration of alignment system of chip mounter based on grating[J]. Optics and Precision Engineering, 2009, 17(10): 2425
Category:
Received: Oct. 14, 2008
Accepted: --
Published Online: Aug. 31, 2010
The Author Email: Wen-chao LIU (wenchaoliuhg@163.com)
CSTR:32186.14.