Spectroscopy and Spectral Analysis, Volume. 32, Issue 6, 1447(2012)

Spectral Characteristic of Short-Arc Xenon Lamp and Application in Solar Simulators

LI Qian*, WANG Cheng, ZHA Jun, and XIA Wei-dong
Author Affiliations
  • [in Chinese]
  • show less

    Due to the inhomogeneous spatial spectral distribution of short-arc xenon lamp, its application is difficult. In the present paper,axially spectral distribution of xenon lamp was measured and temperature distribution was calculated, the temperature distribution was analysed as exponential relationship with arc current density. Therefore,xenon lamp spectral distribution can be made closer to the standard solar simulator spectral distribution by controlling current density.

    Tools

    Get Citation

    Copy Citation Text

    LI Qian, WANG Cheng, ZHA Jun, XIA Wei-dong. Spectral Characteristic of Short-Arc Xenon Lamp and Application in Solar Simulators[J]. Spectroscopy and Spectral Analysis, 2012, 32(6): 1447

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Feb. 28, 2011

    Accepted: --

    Published Online: Jun. 14, 2012

    The Author Email: Qian LI (lq152618379@126.com)

    DOI:10.3964/j.issn.1000-0593(2012)06-1447-04

    Topics