Spectroscopy and Spectral Analysis, Volume. 32, Issue 6, 1447(2012)
Spectral Characteristic of Short-Arc Xenon Lamp and Application in Solar Simulators
Due to the inhomogeneous spatial spectral distribution of short-arc xenon lamp, its application is difficult. In the present paper,axially spectral distribution of xenon lamp was measured and temperature distribution was calculated, the temperature distribution was analysed as exponential relationship with arc current density. Therefore,xenon lamp spectral distribution can be made closer to the standard solar simulator spectral distribution by controlling current density.
Get Citation
Copy Citation Text
LI Qian, WANG Cheng, ZHA Jun, XIA Wei-dong. Spectral Characteristic of Short-Arc Xenon Lamp and Application in Solar Simulators[J]. Spectroscopy and Spectral Analysis, 2012, 32(6): 1447
Received: Feb. 28, 2011
Accepted: --
Published Online: Jun. 14, 2012
The Author Email: Qian LI (lq152618379@126.com)