Infrared and Laser Engineering, Volume. 50, Issue 12, 20210195(2021)

Research on knee joint curvature detection system based on fiber optic MZI-BDB curvature sensor

Lei Ding1... Lie Yu1, Qinlan Xie2 and Lanyan Zhu1 |Show fewer author(s)
Author Affiliations
  • 1State Key Laboratory of New Textile Materials and Advanced Processing Technologies, School of Electrical and Electronic Engineering, Wuhan Textile University, Wuhan 430200, China
  • 2Hubei Key Laboratory of Medical Information Analysis & Tumor Diagnosis and Treatment, School of Biomedical Engineering, South-Central University for Nationalities, Wuhan 430074, China
  • show less

    In the monitoring process of human motion and posture, knee movement information was of great significance in the diagnosis and rehabilitation evaluation of chronic diseases in the middle and old age. The knee directional bending measurement device using a Mach-Zehnder interferometer-based directional bending (MZI-BDB) sensor was presented in this paper. The system consisted of MZI-BDB sensor, swept laser light source, optical fiber coupler, optical fiber isolator, photodetector and signal processing system. MZI-BDB sensor was fabricated by fusion-splicing a section of eccentric core fiber (ECF) between two single-mode fibers (SMF) with core-offset. It was encapsulated in a soft silicone sheet and fixed to the knee joint by a band. When the knee joint was flexed and extended, the MZI-BDB sensor was led to bend, causing the modal interferes of the sensor changes and the resonant wavelength shifted, so as to monitor the bending direction and curvature of the knee joint. The range of measurement of MZI-BDB sensor was 0°-90° at the positive and negative bendings respectively. At the positive bending (bending direction of 0°), the proposed MZI-BDB sensor sensitivity and resolution were 5.29 nm/m-1 and 0.11 m-1 respectively. The sensitivity and resolution were -3.11 nm/m-1 and 0.12 m-1 at the negative bending (bending direction of 180°). The temperature sensitivity of the proposed MZI-BDB was 0.043 nm/℃, which had minimal effect on the experiments. Furthermore, the photoelectric encoder and MZI-BDB sensor were used for data acquisition simultaneously. The experimental results show that the detection system and the photoelectric encoder verification platform are consistent in accuracy and responsiveness.

    Tools

    Get Citation

    Copy Citation Text

    Lei Ding, Lie Yu, Qinlan Xie, Lanyan Zhu. Research on knee joint curvature detection system based on fiber optic MZI-BDB curvature sensor[J]. Infrared and Laser Engineering, 2021, 50(12): 20210195

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical communication and sensing

    Received: Jul. 2, 2021

    Accepted: --

    Published Online: Feb. 9, 2022

    The Author Email:

    DOI:10.3788/IRLA20210195

    Topics