Infrared and Laser Engineering, Volume. 44, Issue 8, 2347(2015)

Analysis and processing of infrared dual waveband radiation ratio based point target

Wang Wenbo* and Wang Yingrui
Author Affiliations
  • [in Chinese]
  • show less

    Infrared dual waveband radiation ratio can denote the blackbody′s temperature information, and can be used for temperature measurement. When using infrared dual waveband radiation ratio to measure the temperature of point target, it is difficult to achieve high-accuracy because of various kinds of noises. The recurrence plot theory was used to analyze the non-station of infrared dual waveband radiation ratio. According to the non-station of infrared dual waveband radiation ratio, the target′s response signal in IR single waveband was processed by moving average filter. The IR dual waveband radiation ratio was processed by wavelet soft-threshold filter. Experimental result indicate that, when the SNR>12, 1 K temperature accuracy can be achieved with above processing method for static point target, and 2 K temperature accuracy can be achieved for slow moving point target.

    Tools

    Get Citation

    Copy Citation Text

    Wang Wenbo, Wang Yingrui. Analysis and processing of infrared dual waveband radiation ratio based point target[J]. Infrared and Laser Engineering, 2015, 44(8): 2347

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 红外技术及应用

    Received: Dec. 11, 2014

    Accepted: Jan. 14, 2015

    Published Online: Jan. 26, 2016

    The Author Email: Wenbo Wang (webowang@163.com)

    DOI:

    Topics