Variable-Focus Hysteresis of Double-Liquid Variable-Focus Lens
By introducing the contact-line static friction, a mechanical model for the contact line in a double-liquid variable-focus lens is established, which is a liquid-liquid-solid three phase system. The mechanical analysis on the contact line of the liquid-liquid-solid three phase system with non-ideal state is done again. On this basis, the Young′s equation is modified, and a reasonable explanation is given for the phenomenon of variable-focus hysteresis. The variable-focus experiment of the double-liquid variable-focus lens with dielectric layer thickness of 2 μm under the applied voltages is performed. A hysteresis curve between the focal length of the double-liquid variable-focus lens and the applied voltage is given. The experimental result agrees very well with the theoretical analysis.
Get Citation
Copy Citation Text
Wang Dazhen, Peng Runling, Chen Jiabi, Zhuang Songlin. Variable-Focus Hysteresis of Double-Liquid Variable-Focus Lens[J]. Acta Optica Sinica, 2011, 31(6): 612001
Category: Instrumentation, Measurement and Metrology
Received: Dec. 31, 2010
Accepted: --
Published Online: May. 11, 2011
The Author Email: Dazhen Wang (show_0357@yahoo.com.cn)