Acta Optica Sinica, Volume. 30, Issue 3, 821(2010)

Measurement of M2 Factor of 1064 nm Pulsed Laser Based on Crossed Defocus Gratings

Ma Haotong*, Xi Fengjie, Zhou Pu, Xu Xiaojun, Chen Jinbao, and Liu Zejin
Author Affiliations
  • [in Chinese]
  • show less

    It is impossible to measure the M2 factor of pulsed laser effectively by using the traditional equipment. For real-time measurement of the M2 factor,two crossed defocus gratings and a lens with short focal length are used to obtain nine beam spots of different positions. The value of M2 factor is determined by calculating the beam waists using the second-moment method and curve-fitting. According to the theory of Gaussian beam propagation and transformation,measured errors as functions of beam waist and positions are analyzed. The analysis shows that the measuring system can work well in a large range. The pulse-to-pulse M2 factors and the change of M2 factors along with the pumping voltages of the 1064 nm Nd:罽AG pulsed laser are measured. The results indicate that measurements of M2 factor of pulsed laser are realized and the system can work successfully for measuring changes of M2 factors during laser working in real time.

    Tools

    Get Citation

    Copy Citation Text

    Ma Haotong, Xi Fengjie, Zhou Pu, Xu Xiaojun, Chen Jinbao, Liu Zejin. Measurement of M2 Factor of 1064 nm Pulsed Laser Based on Crossed Defocus Gratings[J]. Acta Optica Sinica, 2010, 30(3): 821

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and Laser Optics

    Received: Mar. 26, 2009

    Accepted: --

    Published Online: Mar. 11, 2010

    The Author Email: Haotong Ma (mahaotong@163.com)

    DOI:10.3788/aos20103003.0821

    Topics