High Power Laser and Particle Beams, Volume. 35, Issue 12, 124003(2023)
Application of vibration wire measurement technology to pre-alignment units of High Energy Photon Source booster
The pre-alignment units of the High Energy Photon Source (HEPS) are numerious and require extremely high precision in magnet alignment. To verify the magnetic alignment accuracy of the pre-alignment magnet unit in the HEPS booster, vibration wire magnetic center verification measurements need to be carried out in the experimental hall at a certain ratio. Based on the vibration wire system developed in the pre-research stage, a detailed study is conducted to introduce the measurement principle and scanning method of the vibration wire magnetic center. The research focuses on the magnetic center allignment accuracy detection method of the two magnet units in the HEPS booster and conducts verification experiments. A high-precision repeat positioning clamping mechanism for the vibration wire was designed and constructed, and a method for correcting the sag of the vibration wire was studied. The magnetic center scan results of the two magnet units in the booster were analyzed by fitting. The experimental results show that the pre-alignment accuracy requirement of the HEPS booster for a relative position error between magnets better than 50 μm is satisfied. This study provides a reference for accurate measurement of the vibration wire magnetic center in other accelerator pre-allignment magnet units.
Get Citation
Copy Citation Text
Luping Yan, Xiaoyang Liu, Xiaolong Wang, Lan Dong, Tong Wang, Lingling Men, Shang Lu, Yuanying Han, Luyan Zhang, Haoyue Yan, Na Ma, Zhenqiang He, Zhiyong Ke, Bo Li, Jing Liang. Application of vibration wire measurement technology to pre-alignment units of High Energy Photon Source booster[J]. High Power Laser and Particle Beams, 2023, 35(12): 124003
Category:
Received: May. 11, 2023
Accepted: Oct. 12, 2023
Published Online: Dec. 27, 2023
The Author Email: Dong Lan (dongl@ihep.ac.cn)