Spectroscopy and Spectral Analysis, Volume. 31, Issue 1, 21(2011)

Experimental Investigation on Micro-Hollow Cathode Sustained Discharge

XIA Guang-qing1、* and Nader Sadeghi2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Based on micro-hollow cathode discharge (MHCD) as a plasma cathode, a second anode was added to the device for obtaining large volume and uniform plasma at high pressure. The discharge producing condition of MCSD was investigated in the experiments. And the rotational structures of the N2 first positive bands were analyzed with traces of nitrogen added in argon for the measurements of the gas temperature in the MCSD plume. The experimental results show that when the current of the plasma cathode exceeds the threshold, the large volume stable plasma is generated. The gas temperature in the plume is increased a little with increasing the current (0.5~4 mA) and is about 500 K at the pressure of 50 Torr.

    Tools

    Get Citation

    Copy Citation Text

    XIA Guang-qing, Nader Sadeghi. Experimental Investigation on Micro-Hollow Cathode Sustained Discharge[J]. Spectroscopy and Spectral Analysis, 2011, 31(1): 21

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Feb. 12, 2010

    Accepted: --

    Published Online: Mar. 24, 2011

    The Author Email: Guang-qing XIA (gq.xia@dlut.edu.cn)

    DOI:

    Topics