INFRARED, Volume. 43, Issue 10, 1(2022)

Design of High-Resolution and Large-Area-Array Athermalized Infrared Optical System

Hai-qing WU1,2、*
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    The large field-of-view optical passive astheratization system realized by using ordinary infrared optical materials has a technical problem that the number of lenses is large, and it is difficult to realize the lightweight and miniaturization when this system is applied to the current new high-resolution, large-area-array infrared detectors. To this end, a chalcogenide glass with a low temperature coefficient of refractive index is introduced, and an optical passive anthermalization imaging optical system with a working band of 8--12 m, a field-of-view of 40°×325°, an F-number of 10, and a 1280×1024 detector are designed. The design results show that in the operating temperature range of -55--70℃, the modulation transfer function (MTF) values at the detector characteristic frequency of 42 1p/mm are all greater than 035. The imaging performance of the system is good, which can meet the requirements of practical engineering applications.

    Tools

    Get Citation

    Copy Citation Text

    WU Hai-qing. Design of High-Resolution and Large-Area-Array Athermalized Infrared Optical System[J]. INFRARED, 2022, 43(10): 1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 23, 2022

    Accepted: --

    Published Online: Feb. 20, 2023

    The Author Email: Hai-qing WU (whqcust@163.com)

    DOI:10.3969/j.issn.1672-8785.2022.10.001

    Topics