Acta Optica Sinica, Volume. 35, Issue 2, 212001(2015)

High-Accuracy Measurement of Sub-Pixel Image Motion Based on Hybrid Photoelectirc Joint Transform Correlator

Hong Xueting1,2、* and Qian Yixian1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    To measure the sub-pixel image motion which is caused by satellite attitude instability and vibration, an effective approach to measure image motion is presented based on Hybrid Photoelectirc joint transform correlator. Firstly, captured image sequences are optically calculated by joint transform correlator, then the acquired joint power spectrum is processed by Laplace transform, an improved correlation peak is obtained. Lastly, a modified centroid algorithm is proposed to get more accurate motion measurement. Motion measurement based on optical correlation is discussed, and the optical experimental system is also set up. The experimental results show that the measurement error is as low as 0.03 pixel, the accuracy is improved greatly.

    Tools

    Get Citation

    Copy Citation Text

    Hong Xueting, Qian Yixian. High-Accuracy Measurement of Sub-Pixel Image Motion Based on Hybrid Photoelectirc Joint Transform Correlator[J]. Acta Optica Sinica, 2015, 35(2): 212001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jul. 11, 2014

    Accepted: --

    Published Online: Jan. 9, 2015

    The Author Email: Xueting Hong (hongxueting@sina.com)

    DOI:10.3788/aos201535.0212001

    Topics