Laser & Optoelectronics Progress, Volume. 54, Issue 10, 101701(2017)
Blue Light Hazard and Non-Visual Biological Effect of LED Backlight Displayer at Different Color Temperatures
The spectral distributions of LED backlight displayer are measured at different color temperatures. Several function expressions are fitted according to the related initial data. The variations of illumination factor, blue light hazard factor and circadian factor with color are studied with the utilization of MATLAB. In the visible range, the blue-light-ratio of LED backlight displayer at different color temperatures is calculated. The result show that illumination factor decreases with the increase of the age and color temperature; blue light hazard factor and circadian factor increase with the increase of color temperature, and decrease with the increase of the age. When the color temperature is 1200 K, the ratio of blue-light-ratio of the displayer to blue-light-ratio of candle is 0.783, and the ratio is 10.294 when the color temperature is 6500 K. The influences of the blue light hazard and non-visual biological effect on young people are relatively large, and the young people should try to reduce color temperature of LED backlight displayer. This research provides theoretical reference for personalized design and color temperature adjustment of LED backlight displayer.
Get Citation
Copy Citation Text
Yang Chaopu, Fang Wenqing, Liu Mingbao, Li Chun, Zhang Meili, Zhou Chunsheng. Blue Light Hazard and Non-Visual Biological Effect of LED Backlight Displayer at Different Color Temperatures[J]. Laser & Optoelectronics Progress, 2017, 54(10): 101701
Category: Medical Optics and Biotechnology
Received: Apr. 16, 2017
Accepted: --
Published Online: Oct. 9, 2017
The Author Email: Chaopu Yang (ycpslu@163.com)