High Power Laser and Particle Beams, Volume. 34, Issue 2, 026008(2022)

The validation and calculation of highly enriched uranium models in JMCT

Bo Shi and Xiaobo Liu*
Author Affiliations
  • China Academy of Engineering Physics, Institute of Nuclear Physics and Chemistry, Mianyang 621900, China
  • show less

    To verify the accuracy and applicability of JMCT program, 56 models are selected from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Models are established in JLAMT, and the effective multiplication factors are calculated by JMCT and compared with the reference values and MCNP calculation results. The results show that the calculated values of JMCT are generally within three standard deviations of the reference values and the relative deviations between the JMCT calculation results and the reference values are generally less than 2%. The study has verified the accuracy and applicability of JMCT program to a certain extent, and it provides a reference for the subsequent application and verification of JMCT.

    Tools

    Get Citation

    Copy Citation Text

    Bo Shi, Xiaobo Liu. The validation and calculation of highly enriched uranium models in JMCT[J]. High Power Laser and Particle Beams, 2022, 34(2): 026008

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Monte Carlo Methods and Applications

    Received: Aug. 13, 2021

    Accepted: Nov. 2, 2021

    Published Online: Jan. 26, 2022

    The Author Email: Liu Xiaobo (13881190590@163.com)

    DOI:10.11884/HPLPB202234.210352

    Topics