Acta Physica Sinica, Volume. 68, Issue 18, 184301-1(2019)

Measurement and compensation of frequency-dependent attenuation in ultrasonic backscatter signal from cancellous bone

Rui Dong1, Cheng-Cheng Liu1、*, Xun-Bin Cai1, Liu-Lei Shao1, Bo-Yi Li2, and De-An Ta2、*
Author Affiliations
  • 1Institute of Acoustics, School of Physical Science and Engineering, Tongji University, Shanghai 200092, China
  • 2Department of Electronic Engineering, Fudan University, Shanghai 200433, China
  • show less

    Ultrasonic backscatter has been gradually applied to the assessment and diagnosis of bone disease. The heavy frequency-dependent attenuation of ultrasound results in weak ultrasonic signals with poor signal-to-noise ratio and serious wave distortions during propagation in cancellous bone. Ultrasonic attenuation measured with the through-transmission method is an averaged result of ultrasonically interrogated tissues (including the soft tissue, cortical bone and cancellous bone). Therefore, the through-transmission measurements can not accurately provide ultrasonic attenuation of cancellous bone of interest. The purpose of this study is to estimate ultrasonic frequency-dependent attenuation with ultrasonic backscatter measurements and to compensate for the frequency-dependent attenuation in an ultrasonic backscatter signal from cancellous bone. In-vitro ultrasonic backscatter and through-transmission measurements are performed on 16 cancellous bone specimens by using 1.0-MHz transducers. Spatial scans are performed in a 10 mm × 10 mm scanned region with a spatial interval of 0.5 mm for each bone specimen. The frequency slope of ultrasonic attenuation is measured with the ultrasonic through-transmission signals serving as a standard value. Four different algorithms (the spectral shift method, the spectral difference method, the spectral log difference method, and the hybrid method) are used to estimate the frequency slope of ultrasonic attenuation coefficient from ultrasonic backscatter signal. The results show that the frequency-dependent attenuation coefficient ranges from 2.3 dB/mm/MHz to 6.2 dB/mm/MHz for the bovine bone specimens. The through-transmission measured frequency slope of ultrasonic attenuation coefficient is (4.14 ± 1.14) dB/mm/MHz (mean ± standard deviation), and frequency slopes of ultrasonic attenuation coefficient are estimated by four backscattering methods to be (3.88 ± 1.15) dB/mm/MHz, (4.00 ± 0.98) dB/mm/MHz, (3.77 ± 0.84) dB/mm/MHz, and (4.05 ± 0.85) dB/mm/MHz, respectively. The estimated frequency-dependent attenuation is significantly correlated with the standard attenuation value (R = 0.78-0.92, p < 0.01), in which the spectral difference method ( R = 0.91, p < 0.01) and the hybrid method ( R = 0.92, p < 0.01) are more accurate with an estimated error less than 20%. The results prove that it is feasible to measure the frequency-dependent attenuation from ultrasonic backscatter signal of cancellous bone. Based on Fourier transform-inverse Fourier transform, the frequency-dependent attenuation can be compensated.The compensated ultrasonic signals are with significantly improved signal intensity and improved signal-to-noise ratio. This study is conducive to the subsequent ultrasonic backscatter measurement and ultrasonic imaging of cancellous bone.

    Tools

    Get Citation

    Copy Citation Text

    Rui Dong, Cheng-Cheng Liu, Xun-Bin Cai, Liu-Lei Shao, Bo-Yi Li, De-An Ta. Measurement and compensation of frequency-dependent attenuation in ultrasonic backscatter signal from cancellous bone[J]. Acta Physica Sinica, 2019, 68(18): 184301-1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 23, 2019

    Accepted: --

    Published Online: Jun. 28, 2020

    The Author Email: Ta De-An (tda@fudan.edu.cn)

    DOI:10.7498/aps.68.20190599

    Topics