Acta Optica Sinica, Volume. 34, Issue 11, 1106002(2014)

High Voltage Electrostatic Sensor Based on Fabry-Perot Interferometer

Zhang Kaiyu*, Zhao Hong, Yang Yuqiang, and Zhang Weichao
Author Affiliations
  • [in Chinese]
  • show less

    Electrostatic voltmeter plays an important role in the measurement of atternating current (AC) and direct current (DC) high voltage. In order to achieve highly precise measurements in a wide range, an electrostatic voltage sensor using Fabry-Perot (FP) cavity interferometry principle is proposed and fabricated. The measurement electrodes consist of a sensor electrode and a high voltage electrode. FP cavity of the sensor is formed by optical collimator and polyester film aluminized outside. When the high voltage electrode is applied, uniform electric field is produced between polyester film and high voltage electrode. Under the pull of electric field, the shape of polyester film is deformed and the length of FP cavity changes, causing the output spectrum shift of the FP sensor. Phase demodulation method is used to obtain high voltage applied to electrode and realize the electrostatic voltage measurement. The experimental results show that the sensor can measure DC voltage and AC root-mean-square voltage in 5~16 kV. The measurement accuracy is 1.21% of 5 kV to 10 kV and 0.61% of 10 kV to 16 kV. The sensor satisfies the requirement of high voltage measurement.

    Tools

    Get Citation

    Copy Citation Text

    Zhang Kaiyu, Zhao Hong, Yang Yuqiang, Zhang Weichao. High Voltage Electrostatic Sensor Based on Fabry-Perot Interferometer[J]. Acta Optica Sinica, 2014, 34(11): 1106002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Apr. 24, 2014

    Accepted: --

    Published Online: Oct. 13, 2014

    The Author Email: Kaiyu Zhang (gotoayu@126.com)

    DOI:10.3788/aos201434.1106002

    Topics