Laser & Optoelectronics Progress, Volume. 50, Issue 6, 62303(2013)

Study on Influence of Dead Zone on Detection Range and Sensitivity Four-Quadrant Detector

Yang Guishuan1、*, Zhang Zhifeng1, Zhai Yusheng1, Wang Caidong2, Guo Yingying2, Yang Hongjun1, Bai Huanghuang1, and Wang Xinjie2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    This paper introduces the principle of four-quadrant detector and the various factors influencing its detection sensitivity. The influence of dead zone on detection sensitivity is analyzed in detail. The deviation of spot is simulated with Matlab software. The experimental system, including the circuit part and optical part, is designed. Light intensity of each quadrant of the detector is detected by the circuit part. When the width of the dead zone is 0.1 mm, the deviation of spot is measured for the light spot radii of 0.6 mm and 0.4 mm, respectively. The experimental and theoretical results show that the detection sensitivity increases with the size ratio of dead zone to spot increasing.

    Tools

    Get Citation

    Copy Citation Text

    Yang Guishuan, Zhang Zhifeng, Zhai Yusheng, Wang Caidong, Guo Yingying, Yang Hongjun, Bai Huanghuang, Wang Xinjie. Study on Influence of Dead Zone on Detection Range and Sensitivity Four-Quadrant Detector[J]. Laser & Optoelectronics Progress, 2013, 50(6): 62303

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Devices

    Received: Jan. 6, 2013

    Accepted: --

    Published Online: May. 29, 2013

    The Author Email: Guishuan Yang (yguishuan@126.com)

    DOI:10.3788/lop50.062303

    Topics