Journal of Radiation Research and Radiation Processing, Volume. 41, Issue 3, 030302(2023)

Intensity-modulated radiotherapy dose validation based on real respiratory motion parameters in lung cancer patients

Hua CHEN, Yan SHAO, Hao WANG, Hengle GU, Yanhua DUAN, Aihui FENG, Ying HUANG, Yang LIN, Zhenjiong SHEN, and Zhiyong XU*
Author Affiliations
  • Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200030, China
  • show less

    To assess the effect of respiratory movement on dose distribution via intensity-modulated radiotherapy (IMRT) in patients with lung cancer based on real respiratory movement parameters. Twenty-seven patients with lung cancer who underwent four-dimensional computed tomography (4DCT) and received IMRT were analyzed retrospectively to determine the three-dimensional tumor motion amplitude and respiratory period. Based on the above movement parameters, the dose distribution of the tumor on the respiratory movement platform in the head-foot and left-right directions was measured. The difference in IMRT dose distribution between the respiratory motion and static states was compared using the two-dimensional gamma analysis method, and the effect of respiratory motion on dose verification was analyzed. The mean respiratory motion period of patients was 3.3 s, and the mean tumor motion amplitude in the head-foot direction (5.6 mm) was greater than that in the left-right direction (2.1 mm) and the anterior-posterior direction (2.3 mm), with the maximum at 18 mm. The γ-passage rate tended to decrease gradually with the increase intumor motion amplitude. When the tumor motion amplitude was greater than 3 mm, the γ passage rate was less than 95% in most beams. The differences of γ-passage rates grouped by the median respiratory period were statistically significant in the left-right directional motion state. IMRT dose validation in lung canceris affected by the amplitude of tumor motion and the respiratory motion cycle. Respiratory motion management techniques are recommended for patients with a large respiratory motion amplitude to improve the accuracy of dose delivery to the target.

    Tools

    Get Citation

    Copy Citation Text

    Hua CHEN, Yan SHAO, Hao WANG, Hengle GU, Yanhua DUAN, Aihui FENG, Ying HUANG, Yang LIN, Zhenjiong SHEN, Zhiyong XU. Intensity-modulated radiotherapy dose validation based on real respiratory motion parameters in lung cancer patients[J]. Journal of Radiation Research and Radiation Processing, 2023, 41(3): 030302

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Oct. 25, 2022

    Accepted: Dec. 7, 2022

    Published Online: Jul. 24, 2023

    The Author Email:

    DOI:10.11889/j.1000-3436.2022-0111

    Topics