Spectroscopy and Spectral Analysis, Volume. 33, Issue 3, 826(2013)

Determinatoin of Trace Mercury in Sludge Samples by Hydride Generation-Atomic Fluorescence Spectrometry

WANG Yan-yan1、*, SHI Zhi-qiang2, and ZHANG Biao2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Due to the complex matrix characteristic of sludge samples, the research on three wet digestion systems and the conditions of reducing agent, and carrier flow was carried. The experiment conditions of HNO3-HClO4 wet systems, namely 5% HNO3 carrier flow, 0.1% NaBH4 reducing agent, and acidity medium of 5% HNO3+0.05% K2Cr2O7 mixed solution, etc. were finally determined to measure the trace mercury in sludge samples. This recommended method has many advantages, such as accurate and quick detection and simple operation. The determination limit is 0.06 μg·L-1, and the relative standard deviation for 11-time determination of the solution containing 4.0 μg·L-1 Hg is 2.0%. This method for trace mercury in sludge samples by hydride generation-fluorescence (HG-AFS) can be widely used.

    Tools

    Get Citation

    Copy Citation Text

    WANG Yan-yan, SHI Zhi-qiang, ZHANG Biao. Determinatoin of Trace Mercury in Sludge Samples by Hydride Generation-Atomic Fluorescence Spectrometry[J]. Spectroscopy and Spectral Analysis, 2013, 33(3): 826

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jul. 6, 2012

    Accepted: --

    Published Online: Mar. 27, 2013

    The Author Email: Yan-yan WANG (yy_wang320@163.com)