Journal of Applied Optics, Volume. 45, Issue 6, 1219(2024)

Optimization analysis of optoelectronic parameters of laser telemetry systems for hydrogen leakage detection in hydrogen-involved equipment

Meiqi ZHAO1,2,3, Wei ZHOU1,2,3、*, Di WANG2,3,4、**, Yan LYU1,2,3, Yushuang LI1,2,3, Yu PU2,3,4, Dong LI2,3,4, Qidong FENG5, Shuxian CHEN5, and Yilang LUO5
Author Affiliations
  • 1School of Physics and Electronic Engineering, Northeast Petroleum University, Daqing 163318, China
  • 2International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China
  • 3National Key Laboratory of Multi-Resource Collaboration for Green Extraction of Onshore Shale Oil, Daqing 163318, China
  • 4School of Architecture and Civil Engineering, Northeast Petroleum University, Daqing 163318, China
  • 5Hangzhou Hangran Engineering Technology Co.,Ltd., Hangzhou 310008, China
  • show less

    In the scenario of hydrogen leakage, personnel may be exposed to great dangers such as fire, explosion and asphyxiation. In order to effectively reduce the risk of personnel exposure during detection and to monitor hydrogen concentrations in real time, a hydrogen telemetry system based on tunable diode laser absorption spectroscopy (TDLAS) technology under an open light path combined with wavelength modulation system (WMS) technology was developed, in which the simulation modeling was realized by using MATLAB visual modeling and simulation software Simulink. To further improve the detection accuracy and signal-to-noise ratio of the system, the influence of laser scanning parameters on the second-harmonic signal waveform and the influence of different Fresnel lens F numbers on the light intensity received by the detector were comparatively analyzed, and the optimal parameter value was obtained by combining the peak value, peak width, signal-to-noise ratio and signal integrity of the waveform. The results show that the waveform is optimal with the scanning amplitude of 1 V and the scanning frequency of 10 Hz. After parameters optimization, the maximum detection distance of wood board, lime, plastic, and aluminum plate as non-cooperative targets is increased from 1.8 m, 2.4 m, 4 m and 6 m to 2 m, 2.8 m, 5.1 m and 10 m respectively, and the laser-echo incident power of the system is also significantly improved. The hydrogen detection system has the characteristics of wider operating environment, safer detection environment and higher detection accuracy. This research serves as a theoretical foundation for the selection of relevant parameters in practical measurement, and provides theoretical guidance for enhancing the accuracy of system measurement in practical applications.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Meiqi ZHAO, Wei ZHOU, Di WANG, Yan LYU, Yushuang LI, Yu PU, Dong LI, Qidong FENG, Shuxian CHEN, Yilang LUO. Optimization analysis of optoelectronic parameters of laser telemetry systems for hydrogen leakage detection in hydrogen-involved equipment[J]. Journal of Applied Optics, 2024, 45(6): 1219

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 3, 2023

    Accepted: --

    Published Online: Jan. 14, 2025

    The Author Email: ZHOU Wei (周围), WANG Di (王迪(1992—))

    DOI:10.5768/JAO202445.0603002

    Topics