Chinese Optics Letters, Volume. 12, Issue 7, 071201(2014)

Research on error compensation method for dual-beam measurement of roll angle based on rhombic prism (Invited Paper)

Tong Zhang, Qibo Feng, Cunxing Cui, and Bin Zhang

The fabrication deviation of prisms and the error crosstalk are two major factors that produce serious systematic errors in dual-beam roll measurement based on a rhombic prism, and an error compensation method is put forward in this letter to reduce these systematic errors. The rotation matrix, reflection matrix, and refraction matrix are used to calculate and obtain the mathematical relationship model of the roll angle as well as the fabrication deviation of prism and error crosstalk. The fabrication deviation can be obtained through comparison experiments and using the least square method. In this way, the systematic error of the roll measurement caused by fabrication deviation of prism and error crosstalk can be eliminated theoretically. The experimental results show that the maximum error of the roll angle measurement reduces evidently to 3.5′′ from the previous 347.2′′ after compensation.

Tools

Get Citation

Copy Citation Text

Tong Zhang, Qibo Feng, Cunxing Cui, Bin Zhang. Research on error compensation method for dual-beam measurement of roll angle based on rhombic prism (Invited Paper)[J]. Chinese Optics Letters, 2014, 12(7): 071201

Download Citation

EndNote(RIS)BibTexPlain Text
Save article for my favorites
Paper Information

Category: Instrumentation, measurement, and metrology

Received: Jan. 11, 2014

Accepted: Apr. 23, 2014

Published Online: Jun. 26, 2014

The Author Email:

DOI:10.3788/col201412.071201

Topics