Chinese Optics Letters, Volume. 9, Issue 5, 052302(2011)

Influencing factors of microscanning performance based on flat optical component

Xiubao Sui, Lianfa Bai, Qian Chen, and Guohua Gu
Author Affiliations
  • National Defense Key Laboratory of Optoelectronic Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
  • show less

    To decrease the performance difference between the actual microscanning thermal imager and the theoretical value, a germanium lens (placed at a certain angle between the infrared focal plane array and infrared lens) dip angle model of flat optical component microscanning is introduced in this letter. The model is the basis for choosing the dip angle of the germanium lens, which is used in the microscanning thermal imager. In addition, the actual dip angle of the germanium lens is chosen according to the model, the infrared lens parameters of the thermal imager, and the germanium lens parameters of manufacture and installation. Only in this manner can the optimal performance of the microscanning thermal imager based on the flat optical component be obtained. Results of the experiments confirm the accuracy of the conclusions above.

    Tools

    Get Citation

    Copy Citation Text

    Xiubao Sui, Lianfa Bai, Qian Chen, Guohua Gu. Influencing factors of microscanning performance based on flat optical component[J]. Chinese Optics Letters, 2011, 9(5): 052302

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical devices

    Received: Nov. 12, 2010

    Accepted: Jan. 6, 2011

    Published Online: Apr. 22, 2011

    The Author Email:

    DOI:10.3788/COL201109.052302