Acta Optica Sinica, Volume. 24, Issue 5, 597(2004)

L625 Differential Absorption Lidar System for Tropospheric Ozone Measurements

[in Chinese]*, [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    The L625 differential absorption lidar (DIAL) is introduced to measure vertical ozone profiles in the troposphere. System structure, measurement principle and data processing are also described. Comparison measurements of middle and upper tropospheric ozone are made with a couple of wavelength pairs of 289~299 nm and 289~308 nm at Hefei. Measurement results show that the differences between this couple is about 10%. Statistic errors below 10 km altitude are usually less than 2×1011 molecules per cubic centimeter in tropospheric ozone measurement by wavelength pair of 289~308 nm. Systematic errors due to aerosol loading are commonly less than 4%. Characteristics of seasonal variation of tropospheric ozone column contents from 5~15 km altitude are given and analyzed over Hefei. Maximal tropospheric ozone column contents occurred in the second quarter and minimal contents in the third quarter.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. L625 Differential Absorption Lidar System for Tropospheric Ozone Measurements[J]. Acta Optica Sinica, 2004, 24(5): 597

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Mar. 11, 2003

    Accepted: --

    Published Online: Jun. 12, 2006

    The Author Email: (sxhu@aiofm.ac.cn)

    DOI:

    Topics