Spectroscopy and Spectral Analysis, Volume. 34, Issue 9, 2476(2014)
The Field Radiometric Calibration and Validation of ZY-3 Multispectral Sensor
A field calibration campaign of ZY-3 multispectral sensor (MUS) was performed by the China Center for Resources Satellite Data and Application at the Dunhuang site. The reflectance-based method with two-point sites was used to obtain MUS absolute calibration coefficients in 2013. Compared to the calibration results in 2012, the calibration coefficients in 2013 changed by about 1%~8.5% in different bands. The results were also validated by intercalibration method using the Landsat 8 Operational Land Imager (OLI) data. It shows largely good consistency between field calibration and intercalibration. It was concluded that the absolute calibration coefficients were highly reliable.
Get Citation
Copy Citation Text
ZHANG Xue-wen, FU Qiao-yan, HAN Qi-jin, PAN Zhi-qiang, YANG Lei. The Field Radiometric Calibration and Validation of ZY-3 Multispectral Sensor[J]. Spectroscopy and Spectral Analysis, 2014, 34(9): 2476
Received: Oct. 24, 2013
Accepted: --
Published Online: Sep. 15, 2014
The Author Email: Xue-wen ZHANG (zxw29887@163.com)