Acta Optica Sinica, Volume. 29, Issue 9, 2640(2009)

Obtaining High-Power-Density Soft X-ray Source by Using Lens

Chen Dingyang*, Xu Zeping, Qin Yi, and Ning Jiamin
Author Affiliations
  • [in Chinese]
  • show less

    We made soft X-ray lens and combined it with high-temperature plasma radiation which was produced on Qiang-Guang Ⅰ facility. The transmission characters of lens were measured. It is shown that, for the lens manufactured of 2401 X-ray capillaries, when the power density of the incident soft X-ray is 1.0×108 W/cm2, the average transmission efficiency of lens is 9.6%, and the power density 1.15×109 W/cm2 of soft X-ray source without plasma fragment can be obtained at focal point.

    Tools

    Get Citation

    Copy Citation Text

    Chen Dingyang, Xu Zeping, Qin Yi, Ning Jiamin. Obtaining High-Power-Density Soft X-ray Source by Using Lens[J]. Acta Optica Sinica, 2009, 29(9): 2640