Chinese Optics Letters, Volume. 6, Issue 4, 241(2008)

Matched wavelength and incident angle for the diagnostic beam to achieve coherent grating tiling

Xiao Wang*, Qihua Zhu, Yanlei Zuo, Fang Wang, Donghui Lin, Zheng Huang, and Xiaofeng Wei
Author Affiliations
  • Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900
  • show less

    Design and operation of a practical, accurate alignment diagnostic system is important for the grating tiling technology, which is supposed to be applied in a chirped-pulse amplification system to increase the output power. A diagnostic method is proposed and demonstrated for grating tiling. Provided that the wavelength and incident angle of the diagnostic beam are properly set, the far-field of the main laser beam and that of the diagnostic beam can vary in the same way with the tiling errors between the sub-aperture gratings. Therefore, rotational and translational errors can be controlled and compensated according to the far-field of the diagnostic beam. The real-time monitoring and alignment can be achieved without disturbing the main beam.

    Tools

    Get Citation

    Copy Citation Text

    Xiao Wang, Qihua Zhu, Yanlei Zuo, Fang Wang, Donghui Lin, Zheng Huang, Xiaofeng Wei. Matched wavelength and incident angle for the diagnostic beam to achieve coherent grating tiling[J]. Chinese Optics Letters, 2008, 6(4): 241

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Sep. 19, 2007

    Accepted: --

    Published Online: Apr. 21, 2008

    The Author Email: Xiao Wang (wangxiaocn@263.net or wangxcn@mail.ustc.edu.cn)

    DOI:

    Topics