Chinese Journal of Quantum Electronics, Volume. 22, Issue 6, 844(2005)
Measurement for chlorine utilization in a minitype singlet oxygen generator
The measuring system for chlorine utilization was built on a minitype jet singlet oxygen generator (JSOG). The influence of light-source bandwidth, gas temperature, water vapor content and other gas components on the chlorine utilization measured by UV absorptiometry was experimentally and theoretically studied in detail. For a well designed experimental setup, the relative error for the chlorine utilization measurement was about ±2%, which mainlv caused by the noise of the photomultiplier (PMT). On the basis of error analysis, a method to further decrease the measuring error and also extend the measuring range of chlorine utilization was proposed. This study will be helpful for the accurate chlorine utiliza- tion measurement in the singlet oxygen generator (SOG) for a chemical oxygen iodine laser (COIL) system.
Get Citation