Journal of Radiation Research and Radiation Processing, Volume. 42, Issue 2, 020801(2024)

Positioning technique of coded aperture radiation imaging

Wensheng ANG1...2, Shuncheng DONG1,2, Yonghuan DU1,2, Peiyi ZHANG1,2, and Wanxin WEN12,* |Show fewer author(s)
Author Affiliations
  • 1State Key Laboratory of Radiation Medicine and Protection, Soochow University, Suzhou 215123, China
  • 2School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou 215123, China
  • show less

    With the widespread application of nuclear technology and radiation protection, the demand for radioactive sources imaging is increasing. As a high-precision imaging and positioning device for radioactive sources, the coded aperture imaging positioning system can accurately determine the location of radioactive sources and reconstruct their rough shape. This study explores the comparison of the reconstruction effects of various reconstruction algorithms in coded aperture imaging positioning on the position and shape reconstruction of radioactive sources with continuous energy spectra, to determine the advantages and disadvantages of different reconstruction algorithms and their applicable scenarios. Geant4 software was used to simulate the encoded aperture imaging positioning system, and the relevant data were obtained. Thereafter, the δ decoding, fine sampling balance decoding, and convolutional neural network (CNN) algorithms, along with the maximum likelihood maximum expected value method (MLEM) were used to program and reconstruct the location of the radioactive source. The results demonstrate that the four reconstruction algorithms can locate the radioactive source clearly; the δ decoding and fine sampling balance decoding algorithms have artifacts to reconstruct the image; and the CNN algorithm has a poor effect on the reconstruction of line and surface sources, which can be addressed by an extended training set; the contrast to noise ratio (CNR) value of the MLEM algorithm is high, and the reconstruction effect is good, however, some details of the line and surface sources reconstruction will be lost.

    Keywords
    Tools

    Get Citation

    Copy Citation Text

    Wensheng ANG, Shuncheng DONG, Yonghuan DU, Peiyi ZHANG, Wanxin WEN. Positioning technique of coded aperture radiation imaging[J]. Journal of Radiation Research and Radiation Processing, 2024, 42(2): 020801

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Aug. 29, 2023

    Accepted: Jan. 5, 2024

    Published Online: May. 28, 2024

    The Author Email: WEN Wanxin (文万信)

    DOI:10.11889/j.1000-3436.2023-0072

    Topics