Acta Optica Sinica, Volume. 30, Issue 10, 3064(2010)

Design and Error Analysis of Infrared Dual-Channel Band Pass Filter with Wide Rejection Band for Detection Application

Chen Youhua1,2、* and Wang Zhibing1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    In order to meet the requirements of high transmittance in pass bands, high reflectance in rejection bands, small ripple coefficient for detecting 1, 2-propanediol dinitrate with infrared detector cell, an infrared dual-channel band pass filter with proper rejection band has been designed using the combined method of the Herpin refractive index principle and local optimization, as well as choosing PbTe/ZnSe as the material of high/low refractive index. A dual channel filter with pass bands of 5.9~6.2 μm and 11.9~12.2 μm and the average transmittance exceeds 90% and 65% respectively was designed. An error analysis of layer physical thickness and refractive index has been done for the design, which shows that the precision of deposition rate should be controlled within 3.5%, meanwhile, the refractive index accuracy should be lower than 3%, the refractive index has greater effect on the reflectance than the thickness, and the double half-wave film is more sensitive in the changes of refractive index and the thickness.

    Tools

    Get Citation

    Copy Citation Text

    Chen Youhua, Wang Zhibing. Design and Error Analysis of Infrared Dual-Channel Band Pass Filter with Wide Rejection Band for Detection Application[J]. Acta Optica Sinica, 2010, 30(10): 3064

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Thin Films

    Received: Jan. 4, 2010

    Accepted: --

    Published Online: Oct. 24, 2012

    The Author Email: Youhua Chen (tiger1986ren@163.com)

    DOI:10.3788/aos20103010.3064