Acta Optica Sinica, Volume. 36, Issue 3, 301003(2016)

Comparison of Two Close-Loop Control Methods in Adaptive Optics with Wavefront Curvature Sensing

Chen Bo1、*, Yang Jing2, Li Xinyang3, Li Xiaoyang1, and Yang Xu1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less

    For adaptive optics with curvature sensor, two close-loop wavefront control techniques those based on direct fitting method and Laplacian eigenfunctions method are comparative analyzed. The basic principles of two methods are analyzed, and then a numerical simulation model of 36-element curvature adaptive optics is setup and simulations of atmospheric turbulence wavefront aberration correction are carried out. The results show that, comparing with the direct fitting method, the stability and correction accuracy of Laplacian eigenfunctions method are obvious better when the proper modes are chosen, and the stability and accuracy of the direct fitting method are significantly worse when the phase distortion is larger.

    Tools

    Get Citation

    Copy Citation Text

    Chen Bo, Yang Jing, Li Xinyang, Li Xiaoyang, Yang Xu. Comparison of Two Close-Loop Control Methods in Adaptive Optics with Wavefront Curvature Sensing[J]. Acta Optica Sinica, 2016, 36(3): 301003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Sep. 5, 2015

    Accepted: --

    Published Online: Mar. 3, 2016

    The Author Email: Bo Chen (chenbo182001@163.com)

    DOI:10.3788/aos201636.0301003

    Topics