Acta Optica Sinica, Volume. 32, Issue 4, 409002(2012)

Flat-Field Concave Holographic Grating with Broad Spectral Region and High Resolution

Wu Jianfen1,2、*, Zhao Lei1,2, Chen Yongyan1,2, Zhou Chao1,2, Wang Taisheng3, and Wang Yu4
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less

    To realize flat-field concave holographic grating with high resolution and broad spectral region, Namioka concave grating theory, genetic algorithm, simultaneous free-aberration and common diffractive orders are combined to produce the ideas and method of designing flat-field concave holographic grating. A configuration simulation based on flat-field concave holographic grating is presented, whose root mean square (RMS) spot radius of spot diagrams is given. The RMS spot radius is around 11 μm in full spectral region 200~800 nm. While a 10 μm×1 mm entrance slit is used, the illumination spectrum image show that the resolution is 0.25 nm and 0.5 nm in 200~400 nm and 400~800 nm spectral region, respectively. All prove that these ideas and methods are available in designing compact and utilitarian spectrometer.

    Tools

    Get Citation

    Copy Citation Text

    Wu Jianfen, Zhao Lei, Chen Yongyan, Zhou Chao, Wang Taisheng, Wang Yu. Flat-Field Concave Holographic Grating with Broad Spectral Region and High Resolution[J]. Acta Optica Sinica, 2012, 32(4): 409002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Holography

    Received: Aug. 29, 2011

    Accepted: --

    Published Online: Apr. 19, 2012

    The Author Email: Jianfen Wu (wjf_85@163.com)

    DOI:10.3788/aos201232.0409002

    Topics