Journal of Applied Optics, Volume. 45, Issue 6, 1238(2024)
Influence of vignetting on spectral transmittance measurement of infrared optical system
In the infrared spectroscopic transmittance testing system based on the retro-reflective method, the position of the components such as aperture will affect the measurement of spectral transmittance of the infrared lens during measurement. To address this issue, a vignetting model was established to analyze the vignetting of the measurement beam in the testing system, and the vignetting formula generated by aperture and other components placing at different positions was derived. Experimental results show that maintaining the consistency in relative vignetting between the aerial and actual measurements can effectively reduce the effect of vignetting variations on the measurement of spectral transmittance of the infrared lens.
Get Citation
Copy Citation Text
Yiping WU, Shangzhong JIN, Yi DOU, Siwei LI, Xuexin WANG, Tieli HU, Yulan HE, Bing YU, Yunlong ZHANG, Yue YOU. Influence of vignetting on spectral transmittance measurement of infrared optical system[J]. Journal of Applied Optics, 2024, 45(6): 1238
Category:
Received: Oct. 23, 2023
Accepted: --
Published Online: Jan. 14, 2025
The Author Email: WU Yiping (951947625@qq.com)