Journal of Atmospheric and Environmental Optics, Volume. 9, Issue 6, 464(2014)
Design of MOPA Excimer Laser Synchronization System Signal Generator
For MO-PA (master-oscillator pouver amplifier) excimer laser dual-chamber discharge synchronous system, a square wave signal generator based on PIC16F873A microcontroller and DDS (direct digital synthesizer, direct digital frequency synthesizer) chip AD9833 is designed. Comparing to advantages and disadvantages of the traditional simple signal generator and considering application environment of laser operating, the hardware structure of the system and the software process to achieve were discussed. Through experiments and analysis, the results show that the output signal circuit can generate high quality square wave ranging within 1~4 kHz and the frequency error is less than 0.05 Hz.
Get Citation
Copy Citation Text
LI Xi-ru, QIAN Xiao-dong, BAO Jian, LIANG Xu. Design of MOPA Excimer Laser Synchronization System Signal Generator[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(6): 464
Category:
Received: Mar. 21, 2014
Accepted: --
Published Online: Dec. 8, 2014
The Author Email: Xi-ru LI (lixiru@mail.ustc.edu.cn)