Acta Optica Sinica, Volume. 22, Issue 5, 517(2002)
Angular Dependence of 3ω0/2 Emission from Laser-Produced CH Plasmas
A multiply-angle spectra-resolved system was developed. The diagnostic can be used to measure scattered lights at six different observation angles from laser-produced plasmas simultaneously. This diagnostic consists of spectrometer, an array of 6 fibers, and light collectors. The 3ω 0/2 harmonic spectra were measured. The comparison between the observed spectra and a linear theory shows that the electron temperature in the corona of CH plasma produced by 1.053 μm laser is about 0.55 keV.
Get Citation
Copy Citation Text
[in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Angular Dependence of 3ω0/2 Emission from Laser-Produced CH Plasmas[J]. Acta Optica Sinica, 2002, 22(5): 517