Chinese Optics Letters, Volume. 12, Issue s1, S10603(2014)

Measurement of Er3+-doped concentration in optical fiber by using fiber Bragg grating Fabry-rerot cavity ring-down spectrum

Haiyan Chen, Lilin Chen, Cong Chen, Meng Wang, Qi Li, and Kaiqiang Huang

We propose and experimentally demonstrate a novel approach to measure the Er3+ concentration in Er3+-doped silica fiber by fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down spectrum. The relationship between the cavity ring-down time and the Er3+-doped concentration is derived. The results demonstrate that the cavity ring-down time is a function of the temperature of FBG, and an Er3+-doped concentration of 0.3 × 1025 m-3 at the FBG operation temperature of 25℃ is obtained, which is consistent with the commercial Er3+-doped silica fiber parameter. The results obtained have theoretical guidance and develop a new method to measure the ion doped concentration in solid matter.

Tools

Get Citation

Copy Citation Text

Haiyan Chen, Lilin Chen, Cong Chen, Meng Wang, Qi Li, Kaiqiang Huang. Measurement of Er3+-doped concentration in optical fiber by using fiber Bragg grating Fabry-rerot cavity ring-down spectrum[J]. Chinese Optics Letters, 2014, 12(s1): S10603

Download Citation

EndNote(RIS)BibTexPlain Text
Save article for my favorites
Paper Information

Category: Fiber Optics and Optical Communications

Received: Oct. 5, 2013

Accepted: Oct. 18, 2013

Published Online: Jul. 31, 2014

The Author Email:

DOI:10.3788/col201412.s10603

Topics