Acta Optica Sinica, Volume. 31, Issue 10, 1028002(2011)

Influence of Defocusing on Measurement Accuracy of Image Motion of Space Camera

Fan Chao1、*, Li Yingcai2, Fu Hongliang1, and Yang Tiejun1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    To research the influence of the defocusing of CCD on the measurement accuracy when using the joint transform correlator (JTC) to measure the image motion of space camera, the quadratic phase factor induced by defocusing is deduced based on the theory of Fresnel diffraction. Then the measurement error caused by defocusing is studied by emulation and experiment respectively for the JTC which is processed by using the method of power spectrum subtraction and binarization with threshold of zero. The results show that, the measurement error is not more than 10% when the defocusing amount is within 5% of the focal length of the Fourier lens, and the robustness is good; if the defocusing amount is increasing, the measurement error will nonlinearly increase observably. The results of the research can supply provide useful reference for the real-time and online measurement of image motion.

    Tools

    Get Citation

    Copy Citation Text

    Fan Chao, Li Yingcai, Fu Hongliang, Yang Tiejun. Influence of Defocusing on Measurement Accuracy of Image Motion of Space Camera[J]. Acta Optica Sinica, 2011, 31(10): 1028002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Mar. 31, 2011

    Accepted: --

    Published Online: Sep. 20, 2011

    The Author Email: Chao Fan (anfan2003@gmail.com)

    DOI:10.3788/aos201131.1028002

    Topics