Chinese Optics Letters, Volume. 22, Issue 6, 060008(2024)

Quantum projection ghost imaging: a photon-number-selection method [Invited]

Dezhong Cao1, Suheng Zhang2、*, Yanan Zhao2, Cheng Ren1, Jun Zhang1, Baolai Liang2, Baoqing Sun3, and Kaige Wang4、**
Author Affiliations
  • 1Department of Physics, Yantai University, Yantai 264005, China
  • 2College of Physics Science & Technology, Hebei University, Baoding 071002, China
  • 3School of Information Science and Engineering, Shandong University, Qingdao 266237, China
  • 4Department of Physics, Applied Optics Beijing Area Major Laboratory, Beijing Normal University, Beijing 100875, China
  • show less

    We establish a quantum theory of computational ghost imaging and propose quantum projection imaging where object information can be reconstructed by quantum statistical correlation between a certain photon number of a bucket signal and digital micromirror device random patterns. The reconstructed image can be negative or positive, depending on the chosen photon number. In particular, the vacuum state (zero-number) projection produces a negative image with better visibility and contrast-to-noise ratio. The experimental results of quantum projection imaging agree well with theoretical simulations and show that, under the same measurement condition, vacuum projection imaging is superior to conventional and fast first-photon ghost imaging in low-light illumination.

    Keywords

    1. Introduction

    In recent years, low-photon flux imaging technology has attracted extensive attention due to its wide application in various fields, such as remote sensing, biological science, and medical inspection[117]. The light source illuminating the object in most imaging systems is a classical one, such as coherent light or thermal light. Under low-light illumination, only one or a few photons transmitted or reflected by the object can reach the detector with a certain probability. There are two major challenges. First, the zero-count of photons dominates the measurement process. In the intensity correlation, only detected photons act as a valid signal, and all vacuum signals are discarded. This greatly reduces the detection efficiency in imaging. Second, the shot noise in the classical source will lower the signal-to-noise ratio (SNR) of the image. Quantum illumination in the imaging system, such as a single-photon source or a two-photon entangled source, would avoid these problems[16].

    The development of the single-photon detector device and photon-counting techniques provides favorable conditions for low-light imaging. Kirmani et al.[2] proposed a low-flux imaging technique, called first-photon imaging, where for each pixel the number of illumination pulses prior to the first photon detection is used as an initial reflectivity estimate. They claimed that this avoids the Poisson noise inherent in low-flux operation. A similar way of first photon detection, called fast first-photon ghost imaging (FFPGI), can be applied to computational ghost imaging[8]. Sonnleitner et al.[3] utilized an image retrodiction approach that provides the full probability treatment for high-quality imaging data. Morris et al.[4] investigated how to obtain higher-quality images with a small number of photons. The authors attempted to find the answer to the question of how many photons it takes to form an image. Using compressive techniques[14,15], they acquired the reconstructed image of a wasp wing with an average photon-per-pixel ratio of 0.45. A recent paper by Johnson et al. asked the same question as the title of their paper[10]. They pointed out a basic fact that “for intensity images, it seems that one detected photon per image pixel is a realistic guide, but this may be reduced by making further assumptions on the sparsity of an image in a chosen basis, such as spatial frequency.” In any case, experimental results and experience tell us that under low-light conditions, increasing a certain number of photons will significantly improve the image quality.

    Under low-light illumination of a classical source, the quantum effects of light are revealed. In this paper, we set up the quantum theory of computational ghost imaging and propose quantum projection ghost imaging (QPGI). In the quantum projection scheme, the image is reconstructed by a certain number of photons of the object beam correlated with the random patterns of the digital micromirror device (DMD), and it thus can essentially avoid Poisson noise and improve image quality. Of particular interest is that quantum projection of the vacuum state can greatly increase imaging efficiency in the low-photon situation and still obtain a high-quality negative image as well.

    2. Theory

    2.1. General quantum theory for computational imaging

    We first consider the quantum theory of computational ghost imaging. As shown in Fig. 1, computational ghost imaging usually relies on a DMD, which is an array of many micromirrors that flip independently. Each micromirror has two states, 0 and 1, which indicate that incident light is blocked or reflected. While a computer makes independently random control to all micromirrors, the probability function of each micromirror follows a Bernoulli distribution, p(α)={1q,α=0q,α=1,where α is the binary variable and q is the probability that the micromirror pixel is opened (α=1).

    Experimental setup of quantum projection imaging. SCPL represents the supercontinuum pulsed laser. A filter is used to select out the beam wavelength of 660 nm. NDF is the neutral density filter. L is a collective lens. DMD is the digital micromirror device. SPAD is the single-photon avalanche detector. TCSPC is the module of time-correlated single-photon counting. PC is a computer.

    Figure 1.Experimental setup of quantum projection imaging. SCPL represents the supercontinuum pulsed laser. A filter is used to select out the beam wavelength of 660 nm. NDF is the neutral density filter. L is a collective lens. DMD is the digital micromirror device. SPAD is the single-photon avalanche detector. TCSPC is the module of time-correlated single-photon counting. PC is a computer.

    Assume that each micromirror is illuminated by an independent and identical statistical source with the probability distribution p1(n) of photon number n. The joint-probability distribution between the outgoing photon number n and micromirror pixel value α for each micromirror is given by p(α,n)={(1q)δ(n),α=0q×p1(n),α=1,where δ(n)=1 for n=0 and δ(n)=0 for n=1,2,. It reflects a statistical correlation between the two random variables, α and n. If any number of photons join in the bucket detection, the micromirror must be opened. Otherwise, the micromirror is closed with the probability of 1q. This is the key to computational ghost imaging. The photon probability distribution of outgoing light for each micromirror is obtained to be p(1)(n)=αp(α,n)=(1q)δ(n)+qp1(n).

    In comparison with p1(n) of incident light, the probability of the vacuum state is increased, since the 0-state of the micromirror is taken into account. For M independent micromirrors, the photon probability distribution can be derived by the convolutions p(M)(n)=p(1)(n1)p(1)(n2)p(1)(nM)=(1q)M[δ(n)+l=1MCMl(q1q)lpl(n)],where n=n1+n2++nM and CMl=M!/l!(Ml)!. The function pl(n)=p1(n1)p1(n2)p1(nl), where n=n1+n2++nl. Equation (4) is also valid for the case when a uniform source illuminates all DMD mirrors, where pl(n) is the photon probability distribution of any l mirrors illuminated. For the common case of coherent light illumination, the two cases are equivalent. If p1(n) is a Poisson distribution p1(n)=N1neN1/n! with mean photon number N1, pl(n) also satisfies the Poisson distribution with mean photon number lN1. For simplicity, we consider a binary object, and all the photons transmitted or reflected from the object are received by the detector, the so-called bucket detection. Suppose the object is illuminated by M micromirrors, i.e., the object has M pixels. Equation (4) is the photon probability distribution for the bucket signals.

    In a computational imaging scheme where the input light photons are in Poisson statistics (see details in Section 3), Figs. 2(a1) and 2(a2) show the probability distribution of the bucket photons for the two cases. The probability of the vacuum state is clearly separated far from the other photon states because the 0-level of micromirrors only provides the probability of the vacuum state. The experimental results fit well with the theoretical curve, except for the 0 and 1 photon states, due to the stray light and dark counting of the single-photon avalanche detector (SPAD).

    Photon probability distributions of the bucket signals of an object (M = 394) for the two cases: (a1) q = 0.005, N1 = 7.56 and (a2) q = 0.001, N1 = 4.09. Corresponding effective values of object pixels, visibilities, and CNRs of quantum projection imaging are shown in (b1) and (b2), (c1) and (c2), (d1) and (d2), respectively. Bar charts are the theoretical simulations, and circles are the experimental results. In (b1) and (b2), the two lines under the horizontal axis show the range defined by Eq. (24). In (c1), (c2) and (d1), (d2), the lines indicate the corresponding values of CGI for comparison.

    Figure 2.Photon probability distributions of the bucket signals of an object (M = 394) for the two cases: (a1) q = 0.005, N1 = 7.56 and (a2) q = 0.001, N1 = 4.09. Corresponding effective values of object pixels, visibilities, and CNRs of quantum projection imaging are shown in (b1) and (b2), (c1) and (c2), (d1) and (d2), respectively. Bar charts are the theoretical simulations, and circles are the experimental results. In (b1) and (b2), the two lines under the horizontal axis show the range defined by Eq. (24). In (c1), (c2) and (d1), (d2), the lines indicate the corresponding values of CGI for comparison.

    According to the mechanism of computational ghost imaging, for a given binary object all micromirror pixels are divided into two sets: on-micromirror-pixels are imaged onto the object and off-micromirror-pixels never do. The correlation of the bucket signal with the random variable of micromirrors will distinguish an on-micromirror-pixel from an off-one, and an image is formed. Hence, we consider the joint probability function of two sets of micromirrors with the bucket signal. Any off-micromirror-pixel does not correlate with photons in bucket detection, so the joint probability function between the designated micromirror pixel α and the bucket photon number n is written as Poff(α,n)=p(M)(n)p(α).

    For an on-micromirror-pixel, the joint probability distribution of outgoing light is described by Eq. (2). However, any one of on-micromirror-pixels does not correlate with all others. As a result, the joint probability distribution between α and n for the on-micromirror-pixel is given by Pon(α,n)=n1=0np(M1)(nn1)p(α,n1)={(1q)p(M1)(n),α=0p(M)(n)(1q)p(M1)(n),α=1.

    The average photon number of the outgoing beam from the pixel is qN1=nnp(1)(n), and the average photon number of the bucket signal for M pixels is nM=nnp(M)(n)=MqN1.

    The above Eqs. (5) and (6) summarize the basic quantum description of computational ghost imaging. So now we can calculate the correlation coefficients for imaging. We first define the mean value and mean square value of the photon number injected onto each micromirror as N1=nnp1(n),N2=nn2p1(n).

    Using Eq. (3), the corresponding mean values of outgoing photons for the micromirror are n=nnp(1)(n)=qN1,n2=nn2p(1)(n)=qN2.

    Since all micromirrors are independent of each other, the mean value and mean square value of bucket photons are obtained to be nM=nnp(M)(n)=MqN1,n2M=nn2p(M)(n)=(n1+n2++nM)2=Mq[N2+(M1)qN12].

    The first-order correlation coefficients between the binary variable and bucket photon number for off- and on-micromirror-pixels are calculated to be αnoff=α,nαnPoff(α,n)=q2MN1,αnon=α,nαnPon(α,n)=α,n[np(M)(n)n(1q)p(M1)(n)]=q2MN1+q(1q)N1.

    Hence, imaging pixels can be distinguished from non-imaging pixels. The imaging visibility is obtained as V=αnonαnoffαnon+αnoff=11+2Mq/(1q).

    The expression is general, independent of the intensity and statistical nature of the incident light. When q=1/2, V=1/(1+2M) is the same as the visibility of ghost imaging with thermal light correlation. Therefore, computational ghost imaging can greatly improve visibility by decreasing the probability of q. The price paid is a reduction in detection efficiency.

    The second-order correlation coefficients for off- and on-micromirror-pixels are written as α2n2off=αα2p(α)nn2p(M)(n)=q2n2M,α2n2on=nn2pM(n)(1q)nn2p(M1)(n)=n2M(1q)n2M1.

    With these coefficients, we can calculate the contrast-to-noise ratio (CNR)[18], CNR=|αnonαnoff|(α2n2offαnoff2)(α2n2onαnon2).

    2.2. Quantum projection imaging

    Here we propose a novel imaging scheme using quantum projection detection. As shown in Figs. 2(a1) and 2(a2), the bucket photons contain great fluctuations. To bypass the fluctuations, we measure and pick a specific number of photons in the bucket signal and corresponding DMD pixel patterns to form the image.

    From the probability functions [Eqs. (5) and (6)] of computational imaging, we calculate the corresponding conditional probability distributions for a given photon number k, Poff(c)(α|k)=p(α),Pon(c)(α|k)=Pon(α,k)/p(M)(k)={(1q)p(M1)(k)p(M)(k),α=01(1q)p(M1)(k)p(M)(k),α=1.

    With the fact α=α2, the first- and second-order conditional correlation coefficients are obtained equally to be α|koff=α2|koff=ααp(α)=q,α|kon=α2|kon=ααP(c)(α|k)=1(1q)p(M1)p(M)(k).

    The visibility of quantum projection imaging depends on the measurement of k photons, V(k)=α|konα|koffα|kon+α|koff=(1q)[p(M)(k)p(M1)(k)][p(M)(k)p(M1)(k)]+q[p(M)(k)+p(M1)(k)].

    The significant feature of quantum projection imaging compared to conventional imaging is its potential to produce negative images. The condition for the formation of a negative image is p(M)(k)<p(M1)(k).

    In this case, the object signal α|kon is less than the background α|koff. The similar effects of positive and negative ghost imaging by conditional collection of certain range of bucket intensities have been reported both experimentally and theoretically[1922].

    Visibility of quantum projection imaging can be expressed as the similar form to Eq. (12), V(k)=11+2μ(M,k)q/(1q),where the effective value of object pixels is defined as μ(M,k)11p(M1)(k)/p(M)(k).

    The positive and negative values of μ(M,k) correspond to the positive and negative images, respectively. For 0<μ(M,k)<M, quantum projection positive imaging has better visibility than the conventional one. As for the negative values of μ(M,k), however, under the condition of (1q)/q<μ(M,k)<M+(1q)/q,negative imaging has better visibility than the conventional one. The visibility reaches the perfect value when μ(M,k)(1q)/q.

    The CNR of quantum projection imaging is defined as CNR=|α|konα|koff|(α2|koffα|koff2)(α2|konα|kon2).

    Applying Eqs. (18) and (19) to it, we obtain CNR=1q|1p(M1)(k)p(M)(k)|q+[1(1q)p(M1)(k)p(M)(k)]p(M1)(k)p(M)(k)=1qq(2μ22μ+1)+μ1,where μ has been defined by Eq. (23).

    In the same experiment, Figs. 2(a1), 2(a2) and 2(b1), 2(b2) show the effective value of the object pixels μ(M,k) versus the projection photon number k of the bucket signal, and Figs. 2(c1), 2(c2) and 2(d1), 2(d2) show the corresponding visibility and CNR of quantum projection imaging, respectively. In Fig. 2(b1), we can see that the positive imaging and negative imaging exist when the projection photon number k14 and k13, respectively. In the case of positive imaging, μ<M is valid for a larger k (k>23), and it gets the better visibility and CNR [see Figs. 2(c1) and 2(d1)]. However, the vacuum and small photon number (k<10) projections in the negative imaging case also have the better visibility and CNR than the conventional imaging, as long as Eq. (24) is satisfied. Especially for the vacuum projection, μ(M,k=0)(1q)/q, the visibility is almost perfect and the CNR is much higher than the others.

    According to Eq. (4), it can be proved that when Mq<1, the pixel number of the illuminated object is less than 1, and all the quantum projection images are positive except the vacuum projection imaging. Figures 2(a2)2(d2) show the experiment for the case M=394 and q=0.001, which satisfies Mq<1. The vacuum projection imaging has much better visibility than other ways. In most cases, however, the CNR of quantum projection imaging is better than that of conventional imaging.

    It is worth pointing out that in computational ghost imaging, when some frames are selected for imaging, the remaining frames can be superimposed to form a complementary image[22]. In quantum imaging of the k-photon projection, the corresponding complementary image of non-k-photon projection is formed by projecting all other photon numbers except the k-photon. The probability of bucket detection of non k-photon projection is given by p(M)(k¯)=1p(M)(k). Replacing p(M)(k) with p(M)(k¯) in Eqs. (17), (22), (23), and (26), we obtain the visibility and CNR for the complementary image. According to the mathematical formulas, there is in general no simple relationship between a pair of complementary images in terms of the visibility and CNR.

    2.3. Vacuum projection imaging

    In the quantum projection scheme above, a very peculiar option is the vacuum projection, where no photons are detected in the bucket signal. Let p1(0) be the probability of the vacuum state for the incident light on each micromirror. The corresponding vacuum probability for the outgoing light of the micromirror is p(1)(0)=1q+qp1(0). Since all micromirrors are statistically independent of each other, for M micromirrors it has p(M)(0)=[p(1)(0)]M=[1q+qp1(0)]M. Therefore, the condition of negative image p(M)(0)<p(M1)(0) is always satisfied for vacuum projection detection. According to Eq. (20), the visibility of vacuum projection imaging is obtained to be V(k=0)=(1q)[1p1(0)]1q+(1+q)p1(0).

    The corresponding CNR for vacuum projection imaging is written as CNR=|α|0onα|0off|(α2|0offα|0off2)(α2|0onα|0on2)=[1p1(0)]q(1q)[1q+qp1(0)]2+p1(0).

    For the coherent light with average photon number N1, p1(0)=exp(N1). In the vacuum projection cases, imaging visibility and CNR versus the probability of vacuum state are shown in Figs. 3(a1) and 3(b1), and versus the average photon number N1 in Figs. 3(a2) and 3(b2), respectively. Figure 3 tells us that appropriate intensity of driving light ensures a good imaging result of vacuum projection. In the case of a larger average photon number N1, a small probability q can be selected to maintain a large probability of the vacuum state, as shown in Fig. 2.

    (a1), (a2) Visibilities and (b1), (b2) CNRs for vacuum projection imaging, where p1(0) is the vacuum probability for incident light on each micromirror, and N1 is the corresponding average photon number for the Poisson distribution.

    Figure 3.(a1), (a2) Visibilities and (b1), (b2) CNRs for vacuum projection imaging, where p1(0) is the vacuum probability for incident light on each micromirror, and N1 is the corresponding average photon number for the Poisson distribution.

    As indicated in Eqs. (12) and (15) above, the visibility and CNR of computational ghost imaging are inversely proportional to the object pixels. In quantum projection imaging[23], however, the simple inverse relationship no longer holds. Interestingly, for vacuum projection imaging, Eqs. (27) and (28) show that both visibility and CNR are completely independent of object pixels. This feature will greatly improve the image quality and resolution in the face of large and complex objects in computational ghost imaging.

    3. Experiment

    The experimental setup is similar to that for conventional computational ghost imaging, but with a photon counting system replacing the intensity detection, as shown in Fig. 1. The photon counting system consists of an SPAD (Excelitas SPCM-AQRH-W6) and a time-correlated single-photon counting (TCSPC) module (PicoQuant PicoHarp 300) with a time resolution of 4 ps. The optical source is a supercontinuum pulsed laser SCPL (NKT, SuperK EXTREME) with a temporal pulse width of 20 ps and a frequency of 6.49 MHz. After passing through a filter, a beam of wavelength 660 nm is selected to illuminate the object. The laser beam is strongly attenuated by a neutral density filter (NDF, Daheng GCC-3010) before hitting the DMD (Xintong F4100). The object beam is reflected by the DMD and registered by a single-pixel SPAD with the help of a collecting lens, L. The DMD contains 1024×768 independently addressable micromirrors and is used to load random patterns and/or virtual objects (a music note and resolution bars).

    The refresh time of the DMD frame can be set in the range of 5×104sto2×103s. For example, if the refresh time is 103s, the corresponding repetition rate of each frame is 6490 for the pulse frequency 6.49 MHz of the driving laser. We record the total number of photons in these 6490 pulses as the photon counts of the frame. For best experimental results, the photon number measured in the frame must be much smaller than the repetition rate of each frame.

    We first create a virtual object in the DMD, a musical note with M=394 pixels, and consider the two cases of the probabilities that the micromirror is opened, q=0.005 and q=0.001. We measure the photon statistical distributions of the bucket signal, where the average photon numbers are nM=14.9 and nM=1.61, as shown in Figs. 2(a1) and 2(a2), respectively. All the experimental results are shown with the circles and are consistent with the theoretical simulation of Eq. (4) for the Poisson photon distribution of the driving beam. In the experimental results, as we have already pointed out above, the decrease in 0-photon count and the increase in 1- and 2-photon counts are due to the stray light and dark counting of SPAD.

    Figures 2(c1), 2(c2) and 2(d1), 2(d2) are the visibility and CNR for the two cases of quantum projection imaging, respectively. In Fig. 2(c1), the theoretical and experimental results show that negative images occur when the number of projection photons k is not greater than 13; otherwise, positive images occur. The theoretical derivation manifests that when Mq<1, negative imaging can only exist in vacuum projection, and this is verified in Fig. 2(c2). However, the experimental result shows the negative visibility for k=1 photon. This inconsistency is due to the fact that many 0-photon counts have been added into the 1-photon case, as has been shown in Fig. 2(a2). The experimental results of the CNR are shown in Figs. 2(d1) and 2(d2). We can see that the CNR and visibility change synchronously. In general, all the experimental results in Fig. 2 are in good agreement with the theoretical curves.

    In conjunction with Fig. 2, Fig. 4 shows the experimental observation of reconstructed images for a virtual object (music note) of M=394 pixels, and all values of imaging visibility and CNR are listed in the plots. For the three cases of average photon numbers nM and probabilities q of micromirror being opened, we measured the same number of 40,960 DMD frames and reconstructed the images in the four ways: vacuum projection ghost imaging (VPGI), quantum projection ghost imaging with k photons (QPGI), conventional ghost imaging (CGI), and fast first-photon ghost imaging (FFPGI). In case (i) q=0.005 and nM=14.8, the frame numbers recorded in vacuum projection and k=31 photons projection are 3729 and 432, respectively. In case (ii) q=0.001 and nM=1.61, the frame numbers recorded in vacuum projection and k=4 photons projection are 22,968 and 2117, respectively. In case (iii) q=0.001 and nM=1.02, the frame numbers recorded in vacuum projection and k=3 photons projection are 25,535 and 2549, respectively. Obviously, the negative images of vacuum projection are much better than all other positive images in terms of visibility and CNR.

    Reconstructed images of a musical note are observed in four ways: VPGI, QPGI with k-photons, CGI, and FFPGI, in the three cases of different average photon numbers nM and probabilities q.

    Figure 4.Reconstructed images of a musical note are observed in four ways: VPGI, QPGI with k-photons, CGI, and FFPGI, in the three cases of different average photon numbers nM and probabilities q.

    In Fig. 5, the virtual objects are resolution bars (each contains five pixels) in various combinations. We use the same probability q=0.005, the photon number N1=7.86 of each micromirror, and 100,000 DMD frames for all the cases. The experimental results of VPGI, CGI, and non-vacuum projection ghost imaging (NVPGI) for the same objects are plotted in the first, second, and third columns, respectively. The corresponding photon number distributions of the bucket detection are plotted in the fourth column. It is clear that as the number of object pixels increases, both the visibility and CNR of VPGI can maintain high values unchanged, while both decrease in CGI and NVPGI (the complementary imaging of VPGI).

    Reconstructed images of resolution bars in various combinations with VPGI (first column), CGI (second column), and NVPGI (third column). The corresponding photon number distributions of bucket detection are plotted in the fourth column. F is the number recorded in vacuum projection.

    Figure 5.Reconstructed images of resolution bars in various combinations with VPGI (first column), CGI (second column), and NVPGI (third column). The corresponding photon number distributions of bucket detection are plotted in the fourth column. F is the number recorded in vacuum projection.

    Two Chinese characters “zhen” and “kong” (vacuum) as real objects are also used in the experimental scheme of Fig. 1. The experimental results and relevant data are shown in Fig. 6. In all 40,000 DMD frames, 4696 and 7508 frames are assigned to the vacuum projection for “zhen” and “kong”, respectively, and two high-quality negative images are formed with these frames. The reconstructed images of the real objects also demonstrate that VPGI is the best choice with respect to CGI and FFPGI.

    Number of frames versus photon counts and reconstructed images of two Chinese characters with VPGI, CGI, and FFPGI in (a) “zhen” and (b) “kong.” The total number of frames is 40,000.

    Figure 6.Number of frames versus photon counts and reconstructed images of two Chinese characters with VPGI, CGI, and FFPGI in (a) “zhen” and (b) “kong.” The total number of frames is 40,000.

    4. Discussion and Conclusion

    Under strong enough light illumination, both conventional imaging and computational ghost imaging can easily produce the best results. However, in low-light conditions, increasing the exposure time or the number of exposures can significantly improve the image quality. That is, a sufficient number of photons are required to achieve a high-quality image. The answer to the question “how many photons does it take to form an image?” also depends on the quality of the image. Perhaps a more appropriate question to ask is: which way can we observe the best image for a given total number of photons?

    For low-light imaging application, we establish the quantum theory of computational ghost imaging. Based on the quantum statistical correlation between the photon counts of the bucket signal and DMD random patterns, we propose quantum projection imaging, in which the reconstructed image is formed by detecting a particular photon count in the bucket signal. The vacuum state and lower-photon counting projections yield negative imaging, while projections with higher photon counts yield positive imaging. Both theoretical and experimental results have shown that proper selection of quantum projection imaging can lead to better imaging results than CGI and fast first-photon ghost imaging. Quantum projection imaging, as a pure quantum version applied to computational ghost imaging, will attract much attention. In particular, vacuum projection imaging can achieve the best negative image, especially because its visibility and CNR are independent of object pixels. This important feature will greatly promote the wide application of quantum imaging technology in large and complex scenes.

    Tools

    Get Citation

    Copy Citation Text

    Dezhong Cao, Suheng Zhang, Yanan Zhao, Cheng Ren, Jun Zhang, Baolai Liang, Baoqing Sun, Kaige Wang, "Quantum projection ghost imaging: a photon-number-selection method [Invited]," Chin. Opt. Lett. 22, 060008 (2024)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Special Issue: SPECIAL ISSUE ON QUANTUM IMAGING

    Received: Jan. 6, 2024

    Accepted: Apr. 11, 2024

    Published Online: Jun. 24, 2024

    The Author Email: Suheng Zhang (shzhang@hbu.edu.cn), Kaige Wang (wangkg@bnu.edu.cn)

    DOI:10.3788/COL202422.060008

    Topics