Acta Optica Sinica, Volume. 30, Issue 12, 3471(2010)

Static Simulation Experiment of Image Motion Measurement Based on Optical Joint Transform Correlator

Yi Hongwei*, Zhao Hui, Wen Desheng, and Li Yingcai
Author Affiliations
  • [in Chinese]
  • show less

    The optical joint transform correlator (JTC) is an effective technical way for image motion measurement of the space camera. Its basic principles are presented,and performance is evaluated through static simulation experiment. A calibrated image set is tested by the experimental device. The results show that, the measurement accuracy can be controlled below 0.2 pixel in two directions, which is satisfied for the space camera. The influence of centroiding window size on cross-correlation peaks locating is analyzed, based on which, intensity weighted centroiding (IWC) is proposed instead of the traditional centroiding method, by which not only the influence of centroiding window size on image motion measurement is reduced, but also the measurement accuracy is improved.

    Tools

    Get Citation

    Copy Citation Text

    Yi Hongwei, Zhao Hui, Wen Desheng, Li Yingcai. Static Simulation Experiment of Image Motion Measurement Based on Optical Joint Transform Correlator[J]. Acta Optica Sinica, 2010, 30(12): 3471

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Feb. 25, 2010

    Accepted: --

    Published Online: Dec. 7, 2010

    The Author Email: Hongwei Yi (yi_hongwei@126.com)

    DOI:10.3788/aos20103012.3471

    Topics