Electronics Optics & Control, Volume. 23, Issue 4, 98(2016)
A Method for Parallax Testing of Optical Sight
Considering the problem that the parallax of an optical sight with small field-of-view can't be tested with traditional method using collimator tube, we established a parallax testing system by using specialized clamp, two-axis displacement platform, a photoelectric theodolite and optical platform. The photoelectric theodolite is taken as the measurement basis. The maximum parallax is tested when the theodolite is on the extreme position of exit pupil in azimuth/pitching direction. Experimental result showed that the system is stable, and the method is easy in operation and has high measurement accuracy.
Get Citation
Copy Citation Text
ZHANG Bao-chang, YU Zhuang, ZHANG Ping-xin, GUO Li-na, PENG Chuan-gang. A Method for Parallax Testing of Optical Sight[J]. Electronics Optics & Control, 2016, 23(4): 98
Category:
Received: Sep. 14, 2015
Accepted: --
Published Online: Jan. 28, 2021
The Author Email: