Acta Optica Sinica, Volume. 25, Issue 3, 346(2005)

A Testing Method for a MOEMS Optical Switch Using CCD

[in Chinese]*, [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less

    The movement status of the deivce needs to be determined accurately under the driven conditions in the design and fabrication of the optoelectronic devices based on the micro-opto-electro-mechanical systems (MOEMS). Because of the limitation of geometrical dimensions, there are some difficulties in accurate measurement on the driven conditions for MOEMS optical switch. This paper presents an optical method for the measurement of the angular rotation of the cantilever beam on the optical switch. Based on the theoretical analysis, the relations of the angular rotation and the measurable parameters are given, and the optimized results of the measurable parameters are performed. The measure error is less 10% and the experimental results obtained demonstrate that the feasibility of the proposed method to be used for evaluating the driven conditions of the MOEMS optical switch.

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. A Testing Method for a MOEMS Optical Switch Using CCD[J]. Acta Optica Sinica, 2005, 25(3): 346

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Apr. 19, 2004

    Accepted: --

    Published Online: May. 22, 2006

    The Author Email: (dongmingsun@email.jlu.edu.cn)

    DOI:

    Topics